    Midas Sensor Cartridges: SiH4 (low)

    Midas Sensor Cartridges: SiH4 (low)

    MIDAS-S-SHL
    • £160.29


    Midas Sensor Cartridges: SiH4 (low)

    Cartridges are required for all of the transmitters sensors at time of purchase and for replacement. Several Midas cartridges can be configured via the transmitter to read a number of different gases based on a common chemical family. Actual details for the sensor detection range are included in the sensor cartridge data sheet and the Midas technical manual. Midas sensor cartridges can be ordered as part of a kit with the universal Midas transmitter, or as a replacement part with either standard or extended warranty cover.

    Gas Measured: Phosphorous Oxychloride (SiH4 )
    Part No.: MIDAS-S-SHL 1 year standard warranty MIDAS-E-SHL 2 year extended warranty
    Sensor Technology: 3 electrode electrochemical cell
    Measuring Range (ppm): SiH4 0 – 2ppm
    Minimum Alarm 1 Set Point: 0.24ppm
    Repeatability: < ± 5% of measured value
    Linearity: & < ± 10% of measured value
    Response Time: < 3 seconds
    Sensor Cartridge Life Expectancy: ? 24 months under typical application conditions
    Operating Temperature: 0°C to +40°C (32°F to 104°F)
    Operating Humidity: 15 – 90% rH
    Operating Pressure: 90 – 110kPa
    Effect of Position: No effect in typical application
    Calibration Gas: Silane (SiH4)
    Challenge Gas (Bump Test): Hydrogen Sulphide (H2 S)
    Warm Up Time: & < 20 minutes

      Please Note a complete Midas System consists of;

      • Midas or Midas transmitter and cartridge kit
      • Sensor cell (if combo kit not purchased)
      • Sample and exhaust tubing
      • End of line filters