Description
Dräger Tubes For Short Term Measurements: Vinyl Chloride 100/a
Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Vinyl Chloride 100/a).
The tubes come in a pack of 10 tubes and have a shelf life of 2 years.
Application Range:
Standard Measuring Range: | 100 to 3,000 ppm |
Number of Strokes n: | 18 to 1 |
Time for Measurement: | max. 3 min |
Standard Deviation: | ± 30 % |
Colour Change: | violet to light brown |
Ambient Operating Conditions:
Temperature: | 0 to 40 °C |
Absolute Humidity | < 30 mg H2O / L |
Reaction Principle:
CH2=CHCI + MnO4 ~> MnIV + various oxidation products
Cross Sensitivity:
Many organic compounds with C=C double bonds are indicated, but with different sensitivities. It is impossible to differentiate between them. It is impossible to measure vinyl chloride in the presence of dialkyl sulfide..