Dräger Tube -Vinyl Chloride 100/a

DrägerSKU: CH19601

Price:
Sale price£86.57

Description

Dräger Tubes For Short Term Measurements: Vinyl Chloride 100/a

Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Vinyl Chloride 100/a).

The tubes come in a pack of 10 tubes and have a shelf life of 2 years.

Application Range:

Standard Measuring Range: 100 to 3,000 ppm
Number of Strokes n: 18 to 1
Time for Measurement: max. 3 min
Standard Deviation: ± 30 %
Colour Change: violet to light brown

Ambient Operating Conditions:

Temperature: 0 to 40 °C
Absolute Humidity < 30 mg H2O / L

Reaction Principle:

CH2=CHCI + MnO4 ~> MnIV + various oxidation products

Cross Sensitivity:

Many organic compounds with C=C double bonds are indicated, but with different sensitivities. It is impossible to differentiate between them. It is impossible to measure vinyl chloride in the presence of dialkyl sulfide..

For more information on Dräger-Tubes click the image below.

To view our range of Dräger pumps please click below.

You may also like

Recently viewed