Description
Dräger Tubes For Short Term Measurements: Hydrochloric Acid/Nitric Acid 1/a
Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Hydrochloric Acid/Nitric Acid 1/a).
The tubes come in a pack of 10 tubes and have a shelf life of 2 years.
Application Range:
Standard Measuring Range: | 1 to 10 ppm / 1 to 15 ppm |
Number of Strokes n: | 10 |
Time for Measurement: | approx. 1.5 min / approx. 3 min |
Standard Deviation: | ± 30 % |
Colour Change: | blue to yellow |
Ambient Operating Conditions:
Temperature: | 5 to 40 °C for HCI |
Absolute Humidity | max. 15 mg H2O / L |
Reaction Principle:
HCl and/or HNO3 + pH indicator ~> yellow reaction product
Cross Sensitivity:
50 ppm nitrogen dioxide result in almost the same reading as 2 ppm nitric acid. 10 ppm hydrogen sulfide or 5 ppm nitrogen dioxide do not effect the reading. Chlorine concentrations in excess of 1 ppm change the entire indicating layer to a yellow-green..
For more information on Dräger-Tubes click the image below.
To view our range of Dräger pumps please click below.