Dräger Tube -Ethylene 0.1/a (5)

DrägerSKU: 8101331

Price:
Sale price£86.36

Description

Dräger Tubes For Short Term Measurements: Ethylene 0.1/a

Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Ethylene 0.1/a).

The tubes come in a pack of 5 tubes and have a shelf life of 2 years.

Application Range:

Standard Measuring Range: 0.2 to 5 ppm
Number of Strokes n: 20
Time for Measurement: approx. 30 min
Standard Deviation: ± 15 to 30 %
Colour Change: pale yellow to greyish blue

Ambient Operating Conditions:

Temperature: 10 to 40 °C
Absolute Humidity 5 to 20 mg H2O / L

Reaction Principle:

CH2=CH2 + Pd-Molybdate complex ~> blue reaction product

Cross Sensitivity:

Other similar compounds are indicated in addition to ethylene, e.g.: 100 ppm butadiene result in a reading of 1 ppm 50 ppm butylene result in a reading of 1 ppm 5 ppm propylene result in a reading of 1 ppm 20 ppm hydrogen sulfide result in a reading of 2 ppm 25 ppm CO change the indicating layer to a greyish blue..

For more information on Dräger-Tubes click the image below.

To view our range of Dräger pumps please click below.