Description
Dräger Tubes For Short Term Measurements: Carbon Tetrachloride 1/a
Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Tetrachloride 1/a).
The tubes come in a pack of 10 tubes and have a shelf life of 2 years.
Part no | Dräger Tube | Substance | Measurement Range |
8101021 | Carbon Tetrachloride 1/a | Carbon Tetrachloride | 1 to 15 ppm |
Chloropicrine | 1 to 15 ppm | ||
Trichloronitromethane | 1 to 15 ppm |
Application Range:
Standard Measuring Range: | 1 to 15 ppm / 10 to 50 pmm |
Number of Strokes n: | 10 |
Time for Measurement: | approx. 6 min / 3 min |
Standard Deviation: | ± 15 to 20 % |
Colour Change: | white to yellow |
Ambient Operating Conditions:
Temperature: | 15 to 30 °C |
Absolute Humidity | 3 to 15 mg H2O / L |
Reaction Principle:
a) CCI4 + H2S2O7 ~> COCI2 b) COCI2 + Aromatic nitrogen compounds ~> yellow reaction product
Cross Sensitivity:
Chloropicrin and phosgene are indicated with the same sensitivity. It is impossible to measure carbon tetrachloride in the presence of chloropicrin and phosgene. No interference from: 1 ppm chlorine 5 ppm hydrochloric acid 20 ppm methyl bromide 1,000 ppm acetone.
For more information on Dräger-Tubes click the image below.
To view our range of Dräger pumps please click below.