Dräger Tube -Acetone 100/b
Regular price
£74.08 GBP
Contact ISS
Dräger Tubes For Short Term Measurements: Acetone (100/b)
Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Acetone (100/b).
The tubes come in a pack of 10 tubes and have a shelf life of 2 years.
| Part no | Dräger Tube | Substance | Measurement Range |
| CH22901 | Acetone 100/b | Acetone | 100 to 12000 ppm |
| 2-Butanone | 100 to 12000 ppm | ||
| 2-Heptanone | Qualitative | ||
| Hexone (MIBK) | 130 to 15600 ppm | ||
| Methyl-n-Amyl Ketone (2-Heptanone) | Qualitative | ||
| Methyl Ethyl Ketone | 100 to 12000 ppm | ||
| Methyl Isobutylketone (4-Methyl-2-pentanone) | 130 to 15600 ppm | ||
| Methylpropyl Ketone | 130 to 15600 ppm | ||
| 2-Pentanone | 130 to 15600 ppm |
Application Range:
| Standard Measuring Range: | 100 to 12,000 ppm |
| Number of Strokes n: | 10 |
| Time for Measurement: | approx. 4 min. |
| Standard Deviation: | ± 15 to 20 % |
| Colour Change: | pale yellow to yellow |
Ambient Operating Conditions:
| Temperature: | 0 to 40°C |
| Absolute Humidity | 5 to 20 mg H2O/L |
Reaction Principle:
Acetone + 2.4-Dinitrophenylhydrazine ~> yellow hydrazone.
Cross Sensitivity:
Other ketones are indicated but with different sensitivities. Aldehydes are indicated, but not esters. Ammonia causes the indicating layer to turn yellowish brown.
For more information on Dräger-Tubes click the image below.
To view our range of Dräger pumps please click below.
See datasheet in download below.