Home
»
02104-N-6012 Honeywell Excel line-of-sight gas detection system, short range (5 to 40m), 4 to 20mA (source) and Modbus outputs, FM/CSA, fully wired with flexible conduit, electro polished 316SS.
02104-N-6012 Honeywell Excel line-of-sight gas detection system, short range (5 to 40m), 4 to 20mA (source) and Modbus outputs, FM/CSA, fully wired with flexible conduit, electro polished 316SS.
Regular price
£12,111.00 GBP
Contact ISS
P/N: 02104-N-6012
Honeywell Searchline Excel line-of-sight gas detection system
Short range: 5 to 40m
4 to 20mA (source) and Modbus outputs
Standards: FM/CSA
This device is fully wired with flexible conduit and it's electro polished 316SS. It includes Tx, Rx, DX100 termination unit and junction box, 3/4"NPT cable entries, 316SS mounting plates, brackets, hardware and sunshade finished with white painted finish.
-
Since its initial release, Searchline Excel's core design has not changed, and it still leads the industry.
The Searchline Excel is completely impervious to interference from sunlight and other radiation sources, including lightning, arc welding, and flare stacks.
Searchline Excel's patented optical design has shown itself to be the only one that completely solves all of the open path gas detection problems. It does not attempt to conceal basic design shortcomings using software masks, which could jeopardize its ability to detect gas.
In order to maintain accuracy and dependability in all weather conditions, Searchline Excel uses an innovative double band pass filter that completely compensates for fog and/or rain.
Features & Benefits:
- Fast response time gives early warning.
- High sensitivity enables low set points for alarms.
- The alignment-free design simplifies installation.
- Duct flex and vibration tolerance keeps the system online.
- The integrated functional gas test facility enables for simple system checks.
- Contamination-resistant optics lessen the need for unscheduled maintenance.
- Unaffected by water vapor interference
- Immune to catalytic toxins.
- Works in inert environments.
Sample and reference detector alignment:
- Reduced sensitivity to alignment
- Guaranteed performance
- Decreased sensitivity to partial obscurement
Improved hand-held software:
- Simple confirmation of alignment
- Visual indication of target and current signal levels
- Compatible with existing systems
Improved telescope:
- High Power Rifle Telescope
- Easier to align with greater zoom and magnification
- Robust shock resistant design
Quick Specs:
- Response speed: T90 less than 3 seconds (under normal operating conditions)
- Operating temperature: -40° to +65°C (-40° to 150°F)
- Datasheet (PDF) Download