Dräger Sampling Tubes:Activated Charcoal Tube Type B/G

Dräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Activated Charcoal Tube Type B/G

The tubes come in a pack of 1 tubes and have a shelf life of 2 years.

Application Range:

Adsorbate: organic compounds which adsorb on activated charcoal
Sorption agent: coconut shell charcoal
Adsorption layer: 300 mg / 700 mg
Backup layer: 700 mg / 300 mg
Tube length: 125 mm
Outside diameter: 7 mm
Inside diameter: 5 mm

Advice for sample-taking:

This tube can be admits optionally in both directions. The type G tube can be used especially for sample taking of organic compounds, if highly concentrations in the air (e.g. exhaust air) are expecting. For the workplace measurement the tube typ B can be used (Measurement in AGW or TLV Range). When the sampling is finished, the tubes have to be bee closed with the polyethylen caps and the sample derection is to be written down on the sample taking protocol.

Note concerning the analysis:

The enriched volatile organic compounds are analysed in accordance with the procedures recommended by BGIA, DFG, NIOSH, OSHA and HSE. For evaluation of the sampling tubes and systems please contact Dräger..