{"title":"Honeywell RAEGuard 2 Transmitter Photo Ionisation Detector","description":"\u003cp\u003eFor measuring a wide variety of volatile organic compounds (VOCs), the RAEGuard 2 PID is a fixed photoionisation detector (PID). The RAEGuard 2 PID operates on 10 to 28 VDC and provides an analog (4-20mA) three-wire signal output, and RS-485 Modbus digital signal output.\u003c\/p\u003e\n\u003cp\u003eCalibration and maintenance have been greatly simplified as the digital PID sensor module can be easily removed in hazardous locations without tools for calibration or maintenance.\u003c\/p\u003e","products":[{"product_id":"h-d03-0001-000-honeywell-kit-raeguard-2-pid-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model","title":"H-D03-0001-000 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), ATEX\/IECEx, 0.01 – 100 ppm isobutylene equivalent. Diffusion model","description":"\u003cp\u003eP\/N: H-D03-0001-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: ATEX\/IECEx\u003c\/p\u003e\n\u003cp\u003eRange: 0.01 – 100 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003eDiffusion model\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). Performing calibration and maintenance on this detector is a simple process as the digital PID module can be easily removed in unsafe and hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also features a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.01 to 100 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell Analytics","offers":[{"title":"Default Title","offer_id":43199105827063,"sku":"H-D03-0001-000","price":7841.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0004-000-honeywell-kit-raeguard-2-pid-atex-iecex-0-01-100-ppm-isobutylene-equivalent","title":"H-D03-0004-000 Honeywell  Kit, RAEGuard 2 PID (Photoionisation Detector), ATEX\/IECEx, 0.01 – 100 ppm isobutylene equivalent","description":"\u003cp\u003eP\/N: H-D03-0004-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: ATEX\/IECEx\u003c\/p\u003e\n\u003cp\u003eRange: 0.01 – 100 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include: \u003c\/strong\u003eRAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). Performing calibration and maintenance on this detector is a simple process as the digital PID module can be easily removed in unsafe and hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also features a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.01 to 100 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell Analytics","offers":[{"title":"Default Title","offer_id":43199107268855,"sku":"H-D03-0004-000","price":6961.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0004-r00-honeywell-kit-raeguard-2-pid-russia-0-01-100-ppm-isobutylene-equivalent","title":"H-D03-0004-R00 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), Russia, 0.01 – 100 ppm isobutylene equivalent","description":"\u003cp\u003eP\/N: H-D03-0004-R00\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: Russia\u003c\/p\u003e\n\u003cp\u003eRange: 0.01 – 100 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include: \u003c\/strong\u003eRAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). Performing calibration and maintenance on this detector is a simple process as the digital PID module can be easily removed in unsafe and hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also features a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.01 to 100 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell Analytics","offers":[{"title":"Default Title","offer_id":43199107727607,"sku":"H-D03-0004-R00","price":8284.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0015-000-honeywell-kit-raeguard-2-pid-ul-0-01-100-ppm-isobutylene-equivalent-diffusion-model","title":"H-D03-0015-000 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), UL, 0.01 – 100 ppm isobutylene equivalent. Diffusion Model.","description":"\u003cp\u003eP\/N: H-D03-0015-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: UL\u003c\/p\u003e\n\u003cp\u003eRange: 0.01 – 100 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eDiffusion Model\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). Performing calibration and maintenance on this detector is a simple process as the digital PID module can be easily removed in unsafe and hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also features a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.01 to 100 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell Analytics","offers":[{"title":"Default Title","offer_id":43199107858679,"sku":"H-D03-0015-000","price":6757.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0009-000-honeywell-kit-raeguard-2-pid-ul-0-01-100-ppm-isobutylene-equivalent","title":"H-D03-0009-000 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), UL, 0.01 – 100 ppm isobutylene equivalent","description":"\u003cp\u003eP\/N: H-D03-0009-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: UL\u003c\/p\u003e\n\u003cp\u003eRange: 0.01 – 100 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). Performing calibration and maintenance on this detector is a simple process as the digital PID module can be easily removed in unsafe and hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also contains a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.01 to 100 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell Analytics","offers":[{"title":"Default Title","offer_id":43199107924215,"sku":"H-D03-0009-000","price":7909.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0002-000-honeywell-kit-raeguard-2-pid-atex-iecex-0-1-1000-ppm-isobutylene-equivalent-diffusion-model","title":"H-D03-0002-000 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), ATEX\/IECEx, 0.1 – 1000 ppm isobutylene equivalent. Diffusion model.","description":"\u003cp\u003eP\/N: H-D03-0002-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: ATEX\/IECEx\u003c\/p\u003e\n\u003cp\u003eRange: 0.1–1000 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent.\u003c\/p\u003e\n\u003cp\u003eDiffusion model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). Performing calibration and maintenance on this detector is a simple process as the digital PID module can be easily removed in unsafe and hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also contains a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell Analytics","offers":[{"title":"Default Title","offer_id":43199109693687,"sku":"H-D03-0002-000","price":5509.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0005-000-honeywell-kit-raeguard-2-pid-atex-iecex-0-1-1000-ppm-isobutylene-equivalent","title":"H-D03-0005-000 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), ATEX\/IECEx, 0.1 – 1000 ppm isobutylene equivalent","description":"\u003cp\u003eP\/N: H-D03-0005-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: ATEX\/IECEx\u003c\/p\u003e\n\u003cp\u003eRange: 0.1 – 1000 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, and user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). Performing calibration and maintenance on this detector is a simple process as the digital PID module can be easily removed in unsafe and hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also contains a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell Analytics","offers":[{"title":"Default Title","offer_id":43199109791991,"sku":"H-D03-0005-000","price":5570.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0005-r00-honeywell-kit-raeguard-2-pid-russia-0-1-1000-ppm-isobutylene-equivalent","title":"H-D03-0005-R00 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), Russia, 0.1 – 1000 ppm isobutylene equivalent","description":"\u003cp\u003eP\/N: H-D03-0005-R00\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: Russia\u003c\/p\u003e\n\u003cp\u003eRange: 0.1–1000 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). Performing calibration and maintenance on this detector is a simple process as the digital PID module can be easily removed in unsafe and hazardous locations.\u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also contains a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell Analytics","offers":[{"title":"Default Title","offer_id":43199109857527,"sku":"H-D03-0005-R00","price":6628.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0016-000-honeywell-kit-raeguard-2-pid-ul-0-1-1000-ppm-isobutylene-equivalent-diffusion-model","title":"H-D03-0016-000 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), UL, 0.1 – 1000 ppm isobutylene equivalent. Diffusion Model","description":"\u003cp\u003eP\/N: H-D03-0016-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detectors)\u003c\/p\u003e\n\u003cp\u003eStandard: UL\u003c\/p\u003e\n\u003cp\u003eRange: 0.1 – 1000 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003eDiffusion Model\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include: \u003c\/strong\u003eRAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). The digital PID module can be easily removed in hazardous and unsafe locations for calibrations or maintenance, making the process simpler and less bothersome. \u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also contains a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell RAE Systems","offers":[{"title":"Default Title","offer_id":43199109988599,"sku":"H-D03-0016-000","price":6557.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0010-000-honeywell-kit-raeguard-2-pid-ul-0-1-1000-ppm-isobutylene-equivalent","title":"H-D03-0010-000 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), UL, 0.1 – 1000 ppm isobutylene equivalent","description":"\u003cp\u003eP\/N: H-D03-0010-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: UL\u003c\/p\u003e\n\u003cp\u003eRange: 0.1–1000 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, and user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). The digital PID module can be easily removed in hazardous and unsafe locations for calibrations or maintenance, making the process simpler and less bothersome. \u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also contains a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 0.1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell RAE Systems","offers":[{"title":"Default Title","offer_id":43199110119671,"sku":"H-D03-0010-000","price":6330.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0008-000-honeywell-kit-raeguard-2-pid-atex-iecex-1-1000-ppm-isobutylene-equivalent","title":"H-D03-0008-000 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), ATEX\/IECEx, 1 – 1000 ppm isobutylene equivalent","description":"\u003cp\u003eP\/N: H-D03-0008-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: ATEX\/IECEx\u003c\/p\u003e\n\u003cp\u003eRange: 1 – 1000 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003eNote: Correction factors and relays are not available for this detection range\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). The digital PID module can be easily removed in hazardous and unsafe locations for calibrations or maintenance, making the process simpler and less bothersome. \u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also contains a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell RAE Systems","offers":[{"title":"Default Title","offer_id":43199110250743,"sku":"H-D03-0008-000","price":3486.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0008-r00-honeywell-kit-raeguard-2-pid-russia-1-1000-ppm-isobutylene-equivalent","title":"H-D03-0008-R00 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), Russia, 1 – 1000 ppm isobutylene equivalent","description":"\u003cp\u003eP\/N: H-D03-0008-R00\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit, RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: Russia\u003c\/p\u003e\n\u003cp\u003eRange: 1-1000 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003eNote: Correction factors and relays are not available for this detection range\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). The digital PID module can be easily removed in hazardous and unsafe locations for calibrations or maintenance, making the process simpler and less bothersome. \u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also contains a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell RAE Systems","offers":[{"title":"Default Title","offer_id":43199110283511,"sku":"H-D03-0008-R00","price":4147.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"},{"product_id":"h-d03-0012-000-honeywell-kit-raeguard-2-pid-ul-1-1000-ppm-isobutylene-equivalent","title":"H-D03-0012-000 Honeywell Kit, RAEGuard 2 PID (Photoionisation Detector), UL, 1 – 1000 ppm isobutylene equivalent","description":"\u003cp\u003eP\/N: H-D03-0012-000\u003c\/p\u003e\n\u003cp\u003eHoneywell Kit RAEGuard 2 PID (Photoionisation Detector)\u003c\/p\u003e\n\u003cp\u003eStandard: UL\u003c\/p\u003e\n\u003cp\u003eRange: 1-1000 ppm\u003c\/p\u003e\n\u003cp\u003eIsobutylene equivalent\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll kits include:\u003c\/strong\u003e RAEGuard 2 fixed head. DigiPID sensor module, magnetic key, hex service tool, 5 pack of external water trap filters, user manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Overview: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRAEGuard 2 PID is a fixed photoionisation detector (PID) that measures a wide range of volatile organic compounds (VOCs). The digital PID module can be easily removed in hazardous and unsafe locations for calibrations or maintenance, making the process simpler and less bothersome. \u003c\/p\u003e\n\u003cp\u003eThe RAEGuard 2 PID includes features such as a graphic display, a local sound alarm and LED light status indicator. The detector also contains a magnetic key interface which allows it to be calibrated and operational parameters adjusted with the explosion-proof enclosures in place. Additionally, external alarms or process controls can be triggered by configuring Low, High and Fault relays. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuicker response time\u003c\/li\u003e\n\u003cli\u003eReduced maintenance cost due to the easy removal of the sensor module in hazardous locations\u003c\/li\u003e\n\u003cli\u003eLarge UV lamp and better sealing allow for better sensitivity, quicker responses and better resolution, meaning there's no false alarms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Specs:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDigital Smart Sensor Technology\u003c\/li\u003e\n\u003cli\u003eDetection range 1 to 1000 ppm\u003c\/li\u003e\n\u003cli\u003eOperates on 10 to 28 VDC and provides an analogue (4-20mA) three-wire signal output, and RS-485 Modbus digital signal\u003c\/li\u003e\n\u003cli\u003eFault and alarm conditions are indicated by the graphic display and LED light status indicator\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell RAE Systems","offers":[{"title":"Default Title","offer_id":43199110349047,"sku":"H-D03-0012-000","price":4205.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/honeywell-analytics-h-d03-0001-000-honeywell-kit-raeguard-2-pid-photoionisation-detector-atex-iecex-0-01-100-ppm-isobutylene-equivalent-diffusion-model-h-d03-0001-000-1204477056.png?v=1762919864"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/collections\/11.png?v=1746195540","url":"https:\/\/www.isssafety.com\/collections\/honeywell-raeguard-2-transmitter-photo-ionisation-detector.oembed","provider":"Industrial Safety Services","version":"1.0","type":"link"}