{"title":"Dräger X-am® 3500","description":"\u003cp\u003eThe Dräger X-am 3500 was especially designed for clearance measurements. The 1 to 4 gas detector reliably detects flammable gases and vapours as well as O2 (Oxygen), CO (Carbon Monoxide), H2S (Hydrogen Sulphide), NO2 (Nitrogen Dioxide) or SO2 (Sulphur Dioxide). The innovative signalling design and extensive range of accessories ensure optimum safety and easy handling.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","products":[{"product_id":"drager-x-am-3500-ex-o2-1","title":"Drager X am 3500 Ex, O2","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eDrager X am 3500 Ex, O2 (Oxygen)\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecially designed for use with a pump, optimised for clearance measurement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is equipped with a very powerful pump and it can be connected with hoses of up to 45 metres in length. With the use of a pump adapter, it is easy to switch between diffusion and pump mode, meaning the pump only operates when needed. This saves energy, reduces wear and tear, extending the lifespan of the pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is robust and intuitive to operate single-handedly using three function keys. The colour display is easy to read and clearly lays out needed information. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eClear signalling design\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe signal system of the Drager X am 3500 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRed light = gas alarm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eYellow light = device-related alarm, e.g. low battery\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eGreen light = device is ready for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe green glow of the D-light provides a clear indicator, even from a distance, whether the device has been properly tested and is ready for use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn case of an alarm, the X-am 3500 alerts you with colourful alarm LEDs, a loud horn (100 dB(A) at 30 cm), and clearly palpable vibration. Optional four pre-set hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows for easy recognition of the type of hazard based on the symbol displayed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEconomical Fleet Management\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBump test and calibration can be carried out simply and quickly using the Drager X-dock\u003csup\u003e \u003c\/sup\u003ecalibrating station. Operating costs can be kept to a minimum due to the low test gas consumption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInductive charging protects against wear and tear\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe X am 3500 features inductive charging, making it easier to operate and increasing the lifespan of the gas detector. The X am 3500 can be charged (outside of explosion-hazard zones) and measure at the same time, e.g., when in use inside vehicles or on machinery. \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eThe charging cradles can connect with one another, taking up minimal space, and are compatible with existing Drager X am series cradles.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 484pt;\" width=\"645\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 6428; width: 136pt;\" width=\"181\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 1308; width: 28pt;\" width=\"37\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5176; width: 109pt;\" width=\"146\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 2161; width: 46pt;\" width=\"61\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 4209; width: 89pt;\" width=\"118\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 3612; width: 76pt;\" width=\"102\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-height-source: userset; height: 10.2pt;\" height=\"14\"\u003e\n\u003ctd style=\"height: 10.2pt; width: 136pt;\" width=\"181\" class=\"xl67\" height=\"14\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76pt;\" width=\"102\" class=\"xl69\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eCatEx 125 PR\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-catex-125-pr-sensor?_pos=1\u0026amp;_psq=6812950\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6812950\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS O2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=1\u0026amp;_psq=6810881\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eDrägerSensor XXS CO LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–2,000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=2\u0026amp;_psq=6813210\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS H2S LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=3\u0026amp;_psq=6811525\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS NO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=1\u0026amp;_psq=6810884\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS SO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=2\u0026amp;_psq=6810885\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":28808358789200,"sku":"8328412","price":1914.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-draeger-x-am-3500-ex-o2-8328412-1204475058.png?v=1767887665"},{"product_id":"drager-x-am-3500-ex-o2-h2s-lc","title":"Drager X am 3500 Ex, O2, H2S LC","description":"\u003cp\u003e\u003cstrong\u003eDrager X am 3500 Ex, O2 (Oxygen), H2S (Hydrogen Sulphide) LC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecially designed for use with a pump, optimised for clearance measurement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is equipped with a very powerful pump and it can be connected with hoses of up to 45 metres in length. With the use of a pump adapter, it is easy to switch between diffusion and pump mode, meaning the pump only operates when needed. This saves energy, reduces wear and tear, extending the lifespan of the pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is robust and intuitive to operate single-handedly using three function keys. The colour display is easy to read and clearly lays out needed information. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eClear signalling design\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe signal system of the Drager X am 3500 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRed light = gas alarm\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eYellow light = device-related alarm, e.g. low battery\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eGreen light = device is ready for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe green glow of the D-light provides a clear indicator, even from a distance, whether the device has been properly tested and is ready for use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn case of an alarm, the X-am 3500 alerts you with colourful alarm LEDs, a loud horn (100 dB(A) at 30 cm), and clearly palpable vibration. Optional four pre-set hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows for easy recognition of the type of hazard based on the symbol displayed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEconomical Fleet Management\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBump test and calibration can be carried out simply and quickly using the Drager X-dock\u003csup\u003e \u003c\/sup\u003ecalibrating station. Operating costs can be kept to a minimum due to the low test gas consumption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInductive charging protects against wear and tear\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe X am 3500 features inductive charging, making it easier to operate and increasing the lifespan of the gas detector. The X am 3500 can be charged (outside of explosion-hazard zones) and measure at the same time, e.g., when in use inside vehicles or on machinery. \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eThe charging cradles can connect with one another, taking up minimal space, and are compatible with existing Drager X am series cradles.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 484pt;\" width=\"645\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 6428; width: 136pt;\" width=\"181\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 1308; width: 28pt;\" width=\"37\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5176; width: 109pt;\" width=\"146\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 2161; width: 46pt;\" width=\"61\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 4209; width: 89pt;\" width=\"118\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 3612; width: 76pt;\" width=\"102\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-height-source: userset; height: 10.2pt;\" height=\"14\"\u003e\n\u003ctd style=\"height: 10.2pt; width: 136pt;\" width=\"181\" class=\"xl67\" height=\"14\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76pt;\" width=\"102\" class=\"xl69\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eCatEx 125 PR\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-catex-125-pr-sensor?_pos=1\u0026amp;_psq=6812950\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6812950\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS O2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=1\u0026amp;_psq=6810881\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eDrägerSensor XXS CO LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–2,000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=2\u0026amp;_psq=6813210\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS H2S LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=3\u0026amp;_psq=6811525\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS NO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=1\u0026amp;_psq=6810884\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS SO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=2\u0026amp;_psq=6810885\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":28808670183504,"sku":"8328414","price":1969.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-draeger-x-am-3500-ex-o2-8328412-1204475058.png?v=1767887665"},{"product_id":"drager-x-am-3500-ex-o2-co-lc","title":"Drager X am 3500 Ex, O2, CO LC","description":"\u003cp\u003e\u003cstrong\u003eDrager X am 3500 Ex, O2 (Oxygen), CO (Carbon Monoxide) LC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecially designed for use with a pump, optimised for clearance measurement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is equipped with a very powerful pump and it can be connected with hoses of up to 45 metres in length. With the use of a pump adapter, it is easy to switch between diffusion and pump mode, meaning the pump only operates when needed. This saves energy, reduces wear and tear, extending the lifespan of the pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is robust and intuitive to operate single-handedly using three function keys. The colour display is easy to read and clearly lays out needed information. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eClear signalling design\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe signal system of the Drager X am 3500 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRed light = gas alarm\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eYellow light = device-related alarm, e.g. low battery\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eGreen light = device is ready for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe green glow of the D-light provides a clear indicator, even from a distance, whether the device has been properly tested and is ready for use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn case of an alarm, the X-am 3500 alerts you with colourful alarm LEDs, a loud horn (100 dB(A) at 30 cm), and clearly palpable vibration. Optional four pre-set hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows for easy recognition of the type of hazard based on the symbol displayed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEconomical Fleet Management\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBump test and calibration can be carried out simply and quickly using the Drager X-dock\u003csup\u003e \u003c\/sup\u003ecalibrating station. Operating costs can be kept to a minimum due to the low test gas consumption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInductive charging protects against wear and tear\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe X am 3500 features inductive charging, making it easier to operate and increasing the lifespan of the gas detector. The X am 3500 can be charged (outside of explosion-hazard zones) and measure at the same time, e.g., when in use inside vehicles or on machinery. \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eThe charging cradles can connect with one another, taking up minimal space, and are compatible with existing Drager X am series cradles.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 484pt;\" width=\"645\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 6428; width: 136pt;\" width=\"181\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 1308; width: 28pt;\" width=\"37\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5176; width: 109pt;\" width=\"146\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 2161; width: 46pt;\" width=\"61\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 4209; width: 89pt;\" width=\"118\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 3612; width: 76pt;\" width=\"102\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-height-source: userset; height: 10.2pt;\" height=\"14\"\u003e\n\u003ctd style=\"height: 10.2pt; width: 136pt;\" width=\"181\" class=\"xl67\" height=\"14\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76pt;\" width=\"102\" class=\"xl69\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eCatEx 125 PR\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-catex-125-pr-sensor?_pos=1\u0026amp;_psq=6812950\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6812950\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS O2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=1\u0026amp;_psq=6810881\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eDrägerSensor XXS CO LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–2,000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=2\u0026amp;_psq=6813210\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS H2S LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=3\u0026amp;_psq=6811525\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS NO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=1\u0026amp;_psq=6810884\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS SO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=2\u0026amp;_psq=6810885\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 class=\"ng-binding ng-scope\"\u003e\u003cbr\u003e\u003c\/h4\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":28808740569168,"sku":"8328416","price":1969.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-draeger-x-am-3500-ex-o2-8328412-1204475058.png?v=1767887665"},{"product_id":"drager-x-am-3500-ex-o2-co-lc-h2s-lc","title":"Drager X am 3500 Ex, O2, CO LC, H2S LC","description":"\u003cp\u003e\u003cstrong\u003eDrager X am 3500 Ex, O2 (Oxygen), CO (Carbon Monoxide) LC, H2S (Hydrogen Sulphide) LC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecially designed for use with a pump, optimised for clearance measurement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is equipped with a very powerful pump and it can be connected with hoses of up to 45 metres in length. With the use of a pump adapter, it is easy to switch between diffusion and pump mode, meaning the pump only operates when needed. This saves energy, reduces wear and tear, extending the lifespan of the pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is robust and intuitive to operate single-handedly using three function keys. The colour display is easy to read and clearly lays out needed information. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eClear signalling design\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe signal system of the Drager X am 3500 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRed light = gas alarm\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eYellow light = device-related alarm, e.g. low battery\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eGreen light = device is ready for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe green glow of the D-light provides a clear indicator, even from a distance, whether the device has been properly tested and is ready for use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn case of an alarm, the X-am 3500 alerts you with colourful alarm LEDs, a loud horn (100 dB(A) at 30 cm), and clearly palpable vibration. Optional four pre-set hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows for easy recognition of the type of hazard based on the symbol displayed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEconomical Fleet Management\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBump test and calibration can be carried out simply and quickly using the Drager X-dock\u003csup\u003e \u003c\/sup\u003ecalibrating station. Operating costs can be kept to a minimum due to the low test gas consumption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInductive charging protects against wear and tear\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe X am 3500 features inductive charging, making it easier to operate and increasing the lifespan of the gas detector. The X am 3500 can be charged (outside of explosion-hazard zones) and measure at the same time, e.g., when in use inside vehicles or on machinery. \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eThe charging cradles can connect with one another, taking up minimal space, and are compatible with existing Drager X am series cradles.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"645\" style=\"border-collapse: collapse; width: 484pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"181\" style=\"mso-width-source: userset; mso-width-alt: 6428; width: 136pt;\"\u003e \u003ccol width=\"37\" style=\"mso-width-source: userset; mso-width-alt: 1308; width: 28pt;\"\u003e \u003ccol width=\"146\" style=\"mso-width-source: userset; mso-width-alt: 5176; width: 109pt;\"\u003e \u003ccol width=\"61\" style=\"mso-width-source: userset; mso-width-alt: 2161; width: 46pt;\"\u003e \u003ccol width=\"118\" style=\"mso-width-source: userset; mso-width-alt: 4209; width: 89pt;\"\u003e \u003ccol width=\"102\" style=\"mso-width-source: userset; mso-width-alt: 3612; width: 76pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"14\" style=\"mso-height-source: userset; height: 10.2pt;\"\u003e\n\u003ctd height=\"14\" class=\"xl67\" width=\"181\" style=\"height: 10.2pt; width: 136pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl67\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl67\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl69\" width=\"102\" style=\"width: 76pt;\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl68\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eCatEx 125 PR\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–100 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e1 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-catex-125-pr-sensor?_pos=1\u0026amp;_psq=6812950\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6812950\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"mso-height-source: userset; height: 16.5pt;\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"181\" style=\"height: 16.5pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS O2\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=1\u0026amp;_psq=6810881\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl68\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS CO LC\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–2,000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=2\u0026amp;_psq=6813210\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"mso-height-source: userset; height: 16.5pt;\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"181\" style=\"height: 16.5pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS H2S LC\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=3\u0026amp;_psq=6811525\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS NO2\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=1\u0026amp;_psq=6810884\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS SO2\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=2\u0026amp;_psq=6810885\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 class=\"ng-binding ng-scope\"\u003e\u003cbr\u003e\u003c\/h4\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":28808770289744,"sku":"8328418","price":2105.07,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-draeger-x-am-3500-ex-o2-8328412-1204475058.png?v=1767887665"},{"product_id":"drager-x-am-3500-ex-o2-co-lc-no2","title":"Drager X am 3500 Ex, O2, CO LC, NO2","description":"\u003cp\u003e\u003cstrong\u003eDrager X am 3500 Ex, O2 (Oxygen), CO (Carbon Monoxide) LC, NO2 (Nitrogen Dioxide)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecially designed for use with a pump, optimised for clearance measurement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is equipped with a very powerful pump and it can be connected with hoses of up to 45 metres in length. With the use of a pump adapter, it is easy to switch between diffusion and pump mode, meaning the pump only operates when needed. This saves energy, reduces wear and tear, extending the lifespan of the pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is robust and intuitive to operate single-handedly using three function keys. The colour display is easy to read and clearly lays out needed information. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eClear signalling design\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe signal system of the Drager X am 3500 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRed light = gas alarm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eYellow light = device-related alarm, e.g. low battery\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eGreen light = device is ready for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe green glow of the D-light provides a clear indicator, even from a distance, whether the device has been properly tested and is ready for use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn case of an alarm, the X-am 3500 alerts you with colourful alarm LEDs, a loud horn (100 dB(A) at 30 cm), and clearly palpable vibration. Optional four pre-set hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows for easy recognition of the type of hazard based on the symbol displayed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEconomical Fleet Management\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBump test and calibration can be carried out simply and quickly using the Drager X-dock\u003csup\u003e \u003c\/sup\u003ecalibrating station. Operating costs can be kept to a minimum due to the low test gas consumption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInductive charging protects against wear and tear\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe X am 3500 features inductive charging, making it easier to operate and increasing the lifespan of the gas detector. The X am 3500 can be charged (outside of explosion-hazard zones) and measure at the same time, e.g., when in use inside vehicles or on machinery. \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eThe charging cradles can connect with one another, taking up minimal space, and are compatible with existing Drager X am series cradles.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 484pt;\" width=\"645\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 6428; width: 136pt;\" width=\"181\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 1308; width: 28pt;\" width=\"37\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5176; width: 109pt;\" width=\"146\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 2161; width: 46pt;\" width=\"61\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 4209; width: 89pt;\" width=\"118\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 3612; width: 76pt;\" width=\"102\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-height-source: userset; height: 10.2pt;\" height=\"14\"\u003e\n\u003ctd style=\"height: 10.2pt; width: 136pt;\" width=\"181\" class=\"xl67\" height=\"14\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76pt;\" width=\"102\" class=\"xl69\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eCatEx 125 PR\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-catex-125-pr-sensor?_pos=1\u0026amp;_psq=6812950\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6812950\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS O2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=1\u0026amp;_psq=6810881\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eDrägerSensor XXS CO LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–2,000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=2\u0026amp;_psq=6813210\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS H2S LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=3\u0026amp;_psq=6811525\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS NO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=1\u0026amp;_psq=6810884\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS SO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=2\u0026amp;_psq=6810885\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":28829798203472,"sku":"8328422","price":2057.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-draeger-x-am-3500-ex-o2-8328412-1204475058.png?v=1767887665"},{"product_id":"drager-x-am-3500-ex-o2-h2s-lc-so2","title":"Drager X am 3500 Ex, O2, H2S LC, SO2","description":"\u003cp\u003e\u003cstrong\u003eDrager X am 3500 Ex, O2 (Oxygen), H2S (Hydrogen Sulphide) LC, SO2 (Sulphur Dioxide)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecially designed for use with a pump, optimised for clearance measurement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is equipped with a very powerful pump and it can be connected with hoses of up to 45 metres in length. With the use of a pump adapter, it is easy to switch between diffusion and pump mode, meaning the pump only operates when needed. This saves energy, reduces wear and tear, extending the lifespan of the pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is robust and intuitive to operate single-handedly using three function keys. The colour display is easy to read and clearly lays out needed information. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eClear signalling design\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe signal system of the Drager X am 3500 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRed light = gas alarm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eYellow light = device-related alarm, e.g. low battery\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eGreen light = device is ready for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe green glow of the D-light provides a clear indicator, even from a distance, whether the device has been properly tested and is ready for use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn case of an alarm, the X-am 3500 alerts you with colourful alarm LEDs, a loud horn (100 dB(A) at 30 cm), and clearly palpable vibration. Optional four pre-set hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows for easy recognition of the type of hazard based on the symbol displayed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEconomical Fleet Management\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBump test and calibration can be carried out simply and quickly using the Drager X-dock\u003csup\u003e \u003c\/sup\u003ecalibrating station. Operating costs can be kept to a minimum due to the low test gas consumption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInductive charging protects against wear and tear\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe X am 3500 features inductive charging, making it easier to operate and increasing the lifespan of the gas detector. The X am 3500 can be charged (outside of explosion-hazard zones) and measure at the same time, e.g., when in use inside vehicles or on machinery. \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eThe charging cradles can connect with one another, taking up minimal space, and are compatible with existing Drager X am series cradles.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"645\" style=\"border-collapse: collapse; width: 484pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"181\" style=\"mso-width-source: userset; mso-width-alt: 6428; width: 136pt;\"\u003e \u003ccol width=\"37\" style=\"mso-width-source: userset; mso-width-alt: 1308; width: 28pt;\"\u003e \u003ccol width=\"146\" style=\"mso-width-source: userset; mso-width-alt: 5176; width: 109pt;\"\u003e \u003ccol width=\"61\" style=\"mso-width-source: userset; mso-width-alt: 2161; width: 46pt;\"\u003e \u003ccol width=\"118\" style=\"mso-width-source: userset; mso-width-alt: 4209; width: 89pt;\"\u003e \u003ccol width=\"102\" style=\"mso-width-source: userset; mso-width-alt: 3612; width: 76pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"14\" style=\"mso-height-source: userset; height: 10.2pt;\"\u003e\n\u003ctd height=\"14\" class=\"xl67\" width=\"181\" style=\"height: 10.2pt; width: 136pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl67\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl67\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl69\" width=\"102\" style=\"width: 76pt;\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl68\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eCatEx 125 PR\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–100 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e1 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-catex-125-pr-sensor?_pos=1\u0026amp;_psq=6812950\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6812950\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"mso-height-source: userset; height: 16.5pt;\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"181\" style=\"height: 16.5pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS O2\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=1\u0026amp;_psq=6810881\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl68\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS CO LC\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–2,000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=2\u0026amp;_psq=6813210\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"mso-height-source: userset; height: 16.5pt;\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"181\" style=\"height: 16.5pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS H2S LC\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=3\u0026amp;_psq=6811525\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS NO2\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=1\u0026amp;_psq=6810884\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS SO2\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=2\u0026amp;_psq=6810885\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 class=\"ng-binding ng-scope\"\u003e\u003cbr\u003e\u003c\/h4\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":28835569401936,"sku":"8328424","price":2057.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-draeger-x-am-3500-ex-o2-8328412-1204475058.png?v=1767887665"},{"product_id":"drager-set-x-am-3500-ex-o2-co-lc-h2s-lc","title":"Set Drager X am 3500 Ex, O2, CO LC, H2S LC + PS","description":"\u003cp\u003e\u003cstrong\u003eDrager Set X am 3500 Ex, O2 (Oxygen), CO (Carbon Monoxide) LC, H2S (Hydrogen Sulphide) LC + PS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes charging equipment, inductive power unit and power supply\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecially designed for use with a pump, optimised for clearance measurement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is equipped with a very powerful pump and it can be connected with hoses of up to 45 metres in length. With the use of a pump adapter, it is easy to switch between diffusion and pump mode, meaning the pump only operates when needed. This saves energy, reduces wear and tear, extending the lifespan of the pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is robust and intuitive to operate single-handedly using three function keys. The colour display is easy to read and clearly lays out needed information. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eClear signalling design\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe signal system of the Drager X am 3500 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRed light = gas alarm\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eYellow light = device-related alarm, e.g. low battery\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eGreen light = device is ready for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe green glow of the D-light provides a clear indicator, even from a distance, whether the device has been properly tested and is ready for use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn case of an alarm, the X-am 3500 alerts you with colourful alarm LEDs, a loud horn (100 dB(A) at 30 cm), and clearly palpable vibration. Optional four pre-set hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows for easy recognition of the type of hazard based on the symbol displayed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEconomical Fleet Management\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBump test and calibration can be carried out simply and quickly using the Drager X-dock\u003csup\u003e \u003c\/sup\u003ecalibrating station. Operating costs can be kept to a minimum due to the low test gas consumption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInductive charging protects against wear and tear\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe X am 3500 features inductive charging, making it easier to operate and increasing the lifespan of the gas detector. The X am 3500 can be charged (outside of explosion-hazard zones) and measure at the same time, e.g., when in use inside vehicles or on machinery. \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eThe charging cradles can connect with one another, taking up minimal space, and are compatible with existing Drager X am series cradles.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"645\" style=\"border-collapse: collapse; width: 484pt;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"181\" style=\"mso-width-source: userset; mso-width-alt: 6428; width: 136pt;\"\u003e \u003ccol width=\"37\" style=\"mso-width-source: userset; mso-width-alt: 1308; width: 28pt;\"\u003e \u003ccol width=\"146\" style=\"mso-width-source: userset; mso-width-alt: 5176; width: 109pt;\"\u003e \u003ccol width=\"61\" style=\"mso-width-source: userset; mso-width-alt: 2161; width: 46pt;\"\u003e \u003ccol width=\"118\" style=\"mso-width-source: userset; mso-width-alt: 4209; width: 89pt;\"\u003e \u003ccol width=\"102\" style=\"mso-width-source: userset; mso-width-alt: 3612; width: 76pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"14\" style=\"mso-height-source: userset; height: 10.2pt;\"\u003e\n\u003ctd height=\"14\" class=\"xl67\" width=\"181\" style=\"height: 10.2pt; width: 136pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl67\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl67\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl69\" width=\"102\" style=\"width: 76pt;\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl68\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eCatEx 125 PR\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–100 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e1 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-catex-125-pr-sensor?_pos=1\u0026amp;_psq=6812950\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6812950\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"mso-height-source: userset; height: 16.5pt;\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"181\" style=\"height: 16.5pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS O2\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=1\u0026amp;_psq=6810881\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl68\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS CO LC\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–2,000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=2\u0026amp;_psq=6813210\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"mso-height-source: userset; height: 16.5pt;\"\u003e\n\u003ctd height=\"22\" class=\"xl66\" width=\"181\" style=\"height: 16.5pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS H2S LC\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=3\u0026amp;_psq=6811525\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS NO2\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=1\u0026amp;_psq=6810884\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.7pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl66\" width=\"181\" style=\"height: 14.7pt; border-top: none; width: 136pt;\"\u003eDrägerSensor XXS SO2\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"183\" style=\"width: 137pt;\"\u003e\u003cspan class=\"font5\"\u003e0–100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl65\" width=\"179\" style=\"width: 135pt;\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"102\" style=\"border-top: none; width: 76pt;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=2\u0026amp;_psq=6810885\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs.\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":28880540860496,"sku":"8328419","price":2308.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-set-drager-x-am-3500-ex-o2-co-lc-h2s-lc-ps-8328419-1204475059.png?v=1762942427"},{"product_id":"drager-x-am-3500-basic","title":"Drager X am 3500 Basic with Pump Incl. Li Ion battery and pump, without sensors","description":"\u003cp\u003e\u003cstrong\u003eDrager X am 3500 Basic with Pump incl. Li Ion battery and pump, \u003cspan style=\"text-decoration: underline;\"\u003ewithout\u003c\/span\u003e sensors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eSpecially designed for use with a pump, optimised for clearance measurement\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is equipped with a very powerful pump and it can be connected with hoses of up to 45 metres in length. With the use of a pump adapter, it is easy to switch between diffusion and pump mode, meaning the pump only operates when needed. This saves energy, reduces wear and tear, extending the lifespan of the pump.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 3500 is robust and intuitive to operate single-handedly using three function keys. The colour display is easy to read and clearly lays out needed information. Thanks to its compact and robust construction, the device can withstand even the harshest conditions.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eClear signalling design\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe signal system of the Drager X am 3500 is based on a clear colour code, in accordance with the requirements of the EN 60079-29-1, EN 45544-1 and EN 50104:\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRed light = gas alarm\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eYellow light = device-related alarm, e.g. low battery\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eGreen light = device is ready for use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003eThe green glow of the D-light provides a clear indicator, even from a distance, whether the device has been properly tested and is ready for use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIn case of an alarm, the X-am 3500 alerts you with colourful alarm LEDs, a loud horn (100 dB(A) at 30 cm), and clearly palpable vibration. Optional four pre-set hazard symbols are available for the display which explicitly indicate the presence of explosive or toxic gas hazards, for example. This allows for easy recognition of the type of hazard based on the symbol displayed.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eEconomical Fleet Management\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eBump test and calibration can be carried out simply and quickly using the Drager X-dock\u003csup\u003e \u003c\/sup\u003ecalibrating station. Operating costs can be kept to a minimum due to the low test gas consumption.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003eInductive charging protects against wear and tear\u003c\/b\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe X am 3500 features inductive charging, making it easier to operate and increasing the lifespan of the gas detector. The X am 3500 can be charged (outside of explosion-hazard zones) and measure at the same time, e.g., when in use inside vehicles or on machinery. \u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003eThe charging cradles can connect with one another, taking up minimal space, and are compatible with existing Drager X am series cradles.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable style=\"border-collapse: collapse; width: 484pt;\" width=\"645\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 6428; width: 136pt;\" width=\"181\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 1308; width: 28pt;\" width=\"37\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 5176; width: 109pt;\" width=\"146\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 2161; width: 46pt;\" width=\"61\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 4209; width: 89pt;\" width=\"118\"\u003e \u003ccol style=\"mso-width-source: userset; mso-width-alt: 3612; width: 76pt;\" width=\"102\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"mso-height-source: userset; height: 10.2pt;\" height=\"14\"\u003e\n\u003ctd style=\"height: 10.2pt; width: 136pt;\" width=\"181\" class=\"xl67\" height=\"14\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eMeasuring Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl67\" colspan=\"2\"\u003e\u003cstrong\u003e\u003cspan class=\"font6\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 76pt;\" width=\"102\" class=\"xl69\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eCatEx 125 PR\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 % UEG\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-catex-125-pr-sensor?_pos=1\u0026amp;_psq=6812950\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6812950\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS O2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=1\u0026amp;_psq=6810881\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl68\" height=\"19\"\u003eDrägerSensor XXS CO LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–2,000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=2\u0026amp;_psq=6813210\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 16.5pt;\" height=\"22\"\u003e\n\u003ctd style=\"height: 16.5pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"22\"\u003eDrägerSensor XXS H2S LC\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=3\u0026amp;_psq=6811525\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS NO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=1\u0026amp;_psq=6810884\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"mso-height-source: userset; height: 14.7pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.7pt; border-top: none; width: 136pt;\" width=\"181\" class=\"xl66\" height=\"19\"\u003eDrägerSensor XXS SO2\u003c\/td\u003e\n\u003ctd style=\"width: 137pt;\" width=\"183\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0–100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 135pt;\" width=\"179\" class=\"xl65\" colspan=\"2\"\u003e\u003cspan class=\"font5\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 76pt;\" width=\"102\" class=\"xl65\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=2\u0026amp;_psq=6810885\u0026amp;_ss=e\u0026amp;_v=1.0\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4 class=\"ng-binding ng-scope\"\u003e\u003cbr\u003e\u003c\/h4\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":28880600629328,"sku":"8328420","price":1792.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-draeger-x-am-3500-ex-o2-8328412-1204475058.png?v=1767887665"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/collections\/Drager_X-Am_3500_1.png?v=1771511776","url":"https:\/\/www.isssafety.com\/collections\/drager-x-am-3501.oembed","provider":"Industrial Safety Services","version":"1.0","type":"link"}