{"title":"Dräger X-am® 2800","description":"\u003cp\u003eThe Drager X am 2800 multi-gas detector measures up to four gases and is equipped with a shock resistant CatEx sensor.\u003c\/p\u003e\n\u003cp\u003eWith the Dräger Gas Detection Connect software, it offers live data transmission and powerful fleet management.\u003c\/p\u003e\n\u003cp\u003eDesigned for personal monitoring, the Draeger X am 2800 offers you the highest level of safety at a low cost of ownership. It can be equipped with one catalytic Ex-sensor and three electro-chemical sensors at maximum. The instrument supports the X-am pump.\u003c\/p\u003e","products":[{"product_id":"3703918-draeger-x-am-2800-ex-o2-co-h2s-incl-battery","title":"3703918 Drager X am 2800, Ex, O2, CO, H2S, incl. battery","description":"\u003cp class=\"MsoNormal\"\u003eThis portable gas detector measures combustible gases\/vapours, O2 (Oxygen), CO (Carbon Monoxide) and H2S (Hydrogen Sulphide).\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan style=\"mso-ansi-language: EN-US;\" lang=\"EN-US\"\u003eThe Drager X am 2800 Multi Gas Detectors are:\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul type=\"disc\" style=\"margin-top: 0cm;\"\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eRobust in design\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eDust \u0026amp; Waterproof (IP 68)\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFall-resistant up to 2 meters\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFast \u0026amp; Durable Sensors\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eFor Oxygen, Flammable and Toxic Gases\u003c\/li\u003e\n\u003cli style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\" class=\"MsoNormal\"\u003eWireless Live Monitoring and Fleet Management with Dräger Gas Connect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDrager X am 2800, designed for personal protection, is a multi-gas detector that can detect up to 4 gases. This X am 2800 portable gas detector measures combustible gases\/vapours, O2 (Oxygen), CO (Carbon Monoxide) and H2S (Hydrogen Sulphide).\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X am 2800 multi-gas detector has a CatEx sensor that is shock-resistant and can monitor up to four gases.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eStrong fleet management and real-time data transfer are provided by the Drager Gas Detection Connect software.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X-am 2800 is a personal monitoring device that provides the highest level of security at an affordable cost of ownership. It is lightweight and small, making the X am 2800 comfortable and easy to use.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded in this product detector is Bluetooth function, Power supply (NiMH battery), Charger and plug-in power supply unit (for charging of 1 instrument, P.N. \u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-x-am-charging-set-basic-charging-module-with-single-charger?_pos=3\u0026amp;_sid=9d396502e\u0026amp;_ss=r\"\u003e8320333\u003c\/a\u003e). \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"585\" style=\"border-collapse: collapse; width: 632px; height: 484px;\" height=\"492\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"117\" span=\"5\" style=\"width: 126px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"26\" style=\"height: 34.175px;\"\u003e\n\u003ctd height=\"26\" class=\"xl67\" width=\"117\" style=\"height: 34.175px; width: 88pt;\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eDrägerSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl68\" width=\"117\" style=\"width: 88pt; height: 34.175px;\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eSample gases\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl68\" width=\"117\" style=\"width: 88pt; height: 34.175px;\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eMeasuring range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl68\" width=\"117\" style=\"width: 88pt; height: 34.175px;\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl69\" width=\"117\" style=\"width: 88pt; height: 34.175px;\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"86\" style=\"height: 148.163px;\"\u003e\n\u003ctd height=\"86\" class=\"xl70\" width=\"117\" style=\"height: 148.163px; border-top: none; width: 88pt;\"\u003e\n\u003cspan class=\"font6\"\u003eCatEx SR (Shock Resistant)\u003c\/span\u003e\u003cspan class=\"font9\"\u003e\u003csup\u003e \u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"font6\"\u003e(factory setting: methane, other measuring gases selectable)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 148.163px;\"\u003e\u003cspan class=\"font6\"\u003eMethane, Further gases adjustable (propane, pentane, nonane, hydrogen and many more)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 148.163px;\"\u003e\u003cspan class=\"font6\"\u003e0 – 100 % LEL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"117\" style=\"border-top: none; width: 88pt; height: 148.163px;\"\u003e\n\u003cspan class=\"font6\"\u003e1 % LEL,\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"font6\"\u003e0.01 % LEL for\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"font6\"\u003eMethane with selection ch4L (Methane, leak search)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd class=\"xl71\" style=\"border-top: none; height: 148.163px;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/6851900-draeger-draegersensor-catex-sr?_pos=1\u0026amp;_sid=5cec978c6\u0026amp;_ss=r\"\u003e6851900\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"20\" style=\"height: 26.125px;\"\u003e\n\u003ctd height=\"20\" class=\"xl72\" width=\"117\" style=\"height: 26.125px; border-top: none; width: 88pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 26.125px;\"\u003e\u003cspan class=\"font6\"\u003eMethane\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 26.125px;\"\u003e\u003cspan class=\"font6\"\u003e0 – 5 vol% CH4\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 26.125px;\"\u003e\u003cspan class=\"font6\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl73\" width=\"117\" style=\"border-top: none; width: 88pt; height: 26.125px;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"34\" style=\"height: 49.525px;\"\u003e\n\u003ctd height=\"34\" class=\"xl70\" width=\"117\" style=\"height: 49.525px; border-top: none; width: 88pt;\"\u003e\u003cspan class=\"font6\"\u003eXXS O2 (4 alarm thresholds)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 49.525px;\"\u003e\u003cspan class=\"font6\"\u003eOxygen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 49.525px;\"\u003e\u003cspan class=\"font6\"\u003e0 – 25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 49.525px;\"\u003e\u003cspan class=\"font6\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl71\" style=\"border-top: none; height: 49.525px;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=2\u0026amp;_sid=ea059916b\u0026amp;_ss=r\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"59\" style=\"height: 98.8375px;\"\u003e\n\u003ctd height=\"59\" class=\"xl70\" width=\"117\" style=\"height: 98.8375px; border-top: none; width: 88pt;\"\u003e\u003cspan class=\"font6\"\u003eXXS O2 PR (4 alarm thresholds, increased robustness)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 98.8375px;\"\u003e\u003cspan class=\"font6\"\u003eOxygen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 98.8375px;\"\u003e\u003cspan class=\"font6\"\u003e0 – 30 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 98.8375px;\"\u003e\u003cspan class=\"font6\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl71\" style=\"border-top: none; height: 98.8375px;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/draeger-xxs-o2-pr-poison-resistant-0-30-vol?_pos=1\u0026amp;_sid=dbeeb74a0\u0026amp;_ss=r\"\u003e6800530\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 24.8625px;\"\u003e\n\u003ctd height=\"19\" class=\"xl70\" width=\"117\" style=\"height: 24.8625px; border-top: none; width: 88pt;\"\u003e\u003cspan class=\"font6\"\u003eXXS CO LC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 24.8625px;\"\u003e\u003cspan class=\"font6\"\u003eCarbon Monoxide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 24.8625px;\"\u003e\u003cspan class=\"font6\"\u003e0 – 2.000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 24.8625px;\"\u003e\u003cspan class=\"font6\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl71\" style=\"border-top: none; height: 24.8625px;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=3\u0026amp;_sid=e38a42a4b\u0026amp;_ss=r\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"22\" style=\"height: 27.875px;\"\u003e\n\u003ctd height=\"22\" class=\"xl70\" width=\"117\" style=\"height: 27.875px; border-top: none; width: 88pt;\"\u003eXXS H2S LC\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 27.875px;\"\u003e\u003cspan class=\"font6\"\u003eHydrogen Sulphide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 27.875px;\"\u003e\u003cspan class=\"font6\"\u003e0 – 200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 27.875px;\"\u003e\u003cspan class=\"font6\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl71\" style=\"border-top: none; height: 27.875px;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=4\u0026amp;_sid=45b77f5e3\u0026amp;_ss=r\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 24.8625px;\"\u003e\n\u003ctd height=\"19\" class=\"xl70\" width=\"117\" style=\"height: 24.8625px; border-top: none; width: 88pt;\"\u003eXXS NO2\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 24.8625px;\"\u003e\u003cspan class=\"font6\"\u003eNitrogen Dioxide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 24.8625px;\"\u003e\u003cspan class=\"font6\"\u003e0 – 50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"117\" style=\"border-top: none; width: 88pt; height: 24.8625px;\"\u003e\u003cspan class=\"font6\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl71\" style=\"border-top: none; height: 24.8625px;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=2\u0026amp;_sid=f7e720bbb\u0026amp;_ss=r\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"33\" style=\"height: 49.575px;\"\u003e\n\u003ctd height=\"33\" class=\"xl74\" width=\"117\" style=\"height: 49.575px; border-top: none; width: 88pt;\"\u003e\u003cspan class=\"font6\"\u003eXXS SO2 (with KX-Filter)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl75\" width=\"117\" style=\"border-top: none; width: 88pt; height: 49.575px;\"\u003e\u003cspan class=\"font6\"\u003eSulphur Dioxide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl75\" width=\"117\" style=\"border-top: none; width: 88pt; height: 49.575px;\"\u003e\u003cspan class=\"font6\"\u003e0 – 100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl75\" width=\"117\" style=\"border-top: none; width: 88pt; height: 49.575px;\"\u003e\u003cspan class=\"font6\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"xl76\" style=\"border-top: none; height: 49.575px;\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=3\u0026amp;_sid=0f716b0f9\u0026amp;_ss=r\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(90, 83, 87);\"\u003eAll sensors: Response time T90: \u0026lt; 15 s (CatEx SR: specification for gas methane\/propane)\u003c\/span\u003e\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":43735981719799,"sku":"3703918","price":1289.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-3703918-drager-x-am-2800-ex-o2-co-h2s-incl-battery-3703918-1204475201.png?v=1762954793"},{"product_id":"3703919-draeger-x-am-2800-ex-o2-co-h2s-power-set","title":"Drager X am 2800 Multi Gas Detector, measures ex (combustible gases\/vapours), O2 (Oxygen), CO (Carbon Monoxide) and H2S (Hydrogen Sulphide) P\/N: 3703919","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\"\u003eThe Drager X am 2800 Multi Gas Detectors are:\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRobust in Design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDust \u0026amp; Waterproof (IP 68)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFall-resistant up to 2 metres\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFast \u0026amp; Durable Sensors\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFor Oxygen, Flammable and Toxic Gases\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eWireless Live Monitoring and Fleet Management with Dräger Gas Connect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eContact us to discuss your needs and for the best price on this device(s).\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDraeger X-am 2800, designed for personal protection, is a multi-gas detector that can detect 4 gases. This X am 2800 portable gas detector measures combustible gases\/vapours, O2 (Oxygen), CO (Carbon Monoxide) and H2S (Hydrogen Sulphide).\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X-am 2800 multi-gas detector has a CatEx sensor that is particularly shock-resistant and can monitor up to four gases.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eStrong fleet management and real-time data transfer are provided by the Dräger Gas Detection Connect software.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X-am 2800 is a personal monitoring device that provides the highest level of security at an affordable cost of ownership. It is lightweight and small, making the X-am 2800 easy to use and comfortable.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded in this product detector is Bluetooth function, Power supply (NiMH battery), Charger and plug-in power supply unit (for charging of 1 instrument, P.N. \u003ca rel=\"noopener\" title=\"Drager Charging Set\" href=\"https:\/\/www.isssafety.com\/products\/drager-x-am-charging-set-basic-charging-module-with-single-charger\" target=\"_blank\"\u003e8320333\u003c\/a\u003e). \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable height=\"492\" style=\"border-collapse: collapse; width: 632px; height: 484px;\" width=\"585\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 126px;\" span=\"5\" width=\"117\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 34.175px;\" height=\"26\"\u003e\n\u003ctd style=\"height: 34.175px; width: 88pt;\" width=\"117\" class=\"xl67\" height=\"26\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eDrägerSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88pt; height: 34.175px;\" width=\"117\" class=\"xl68\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eSample gases\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88pt; height: 34.175px;\" width=\"117\" class=\"xl68\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eMeasuring range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88pt; height: 34.175px;\" width=\"117\" class=\"xl68\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88pt; height: 34.175px;\" width=\"117\" class=\"xl69\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 148.163px;\" height=\"86\"\u003e\n\u003ctd style=\"height: 148.163px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"86\"\u003e\n\u003cspan class=\"font6\"\u003eCatEx SR (Shock Resistant)\u003c\/span\u003e\u003cspan class=\"font9\"\u003e\u003csup\u003e \u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"font6\"\u003e(factory setting: methane, other measuring gases selectable)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 148.163px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eMethane, Further gases adjustable (propane, pentane, nonane, hydrogen and many more)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 148.163px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 100 % LEL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 148.163px;\" width=\"117\" class=\"xl66\"\u003e\n\u003cspan class=\"font6\"\u003e1 % LEL,\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"font6\"\u003e0.01 % LEL for\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"font6\"\u003eMethane with selection ch4L (Methane, leak search)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 148.163px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/6851900-draeger-draegersensor-catex-sr?_pos=1\u0026amp;_sid=5cec978c6\u0026amp;_ss=r\"\u003e6851900\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.125px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 26.125px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl72\" height=\"20\"\u003e \u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 26.125px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eMethane\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 26.125px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 5 vol% CH4\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 26.125px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 26.125px;\" width=\"117\" class=\"xl73\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 49.525px;\" height=\"34\"\u003e\n\u003ctd style=\"height: 49.525px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"34\"\u003e\u003cspan class=\"font6\"\u003eXXS O2 (4 alarm thresholds)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.525px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eOxygen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.525px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.525px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 49.525px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=2\u0026amp;_sid=ea059916b\u0026amp;_ss=r\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 98.8375px;\" height=\"59\"\u003e\n\u003ctd style=\"height: 98.8375px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"59\"\u003e\u003cspan class=\"font6\"\u003eXXS O2 PR (4 alarm thresholds, increased robustness)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 98.8375px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eOxygen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 98.8375px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 30 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 98.8375px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 98.8375px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/draeger-xxs-o2-pr-poison-resistant-0-30-vol?_pos=1\u0026amp;_sid=dbeeb74a0\u0026amp;_ss=r\"\u003e6800530\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.8625px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 24.8625px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"19\"\u003e\u003cspan class=\"font6\"\u003eXXS CO LC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eCarbon Monoxide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 2.000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 24.8625px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=3\u0026amp;_sid=e38a42a4b\u0026amp;_ss=r\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.875px;\" height=\"22\"\u003e\n\u003ctd style=\"height: 27.875px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"22\"\u003eXXS H2S LC\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 27.875px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eHydrogen Sulphide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 27.875px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 27.875px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 27.875px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=4\u0026amp;_sid=45b77f5e3\u0026amp;_ss=r\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.8625px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 24.8625px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"19\"\u003eXXS NO2\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eNitrogen Dioxide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 24.8625px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=2\u0026amp;_sid=f7e720bbb\u0026amp;_ss=r\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 49.575px;\" height=\"33\"\u003e\n\u003ctd style=\"height: 49.575px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl74\" height=\"33\"\u003e\u003cspan class=\"font6\"\u003eXXS SO2 (with KX-Filter)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.575px;\" width=\"117\" class=\"xl75\"\u003e\u003cspan class=\"font6\"\u003eSulphur Dioxide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.575px;\" width=\"117\" class=\"xl75\"\u003e\u003cspan class=\"font6\"\u003e0 – 100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.575px;\" width=\"117\" class=\"xl75\"\u003e\u003cspan class=\"font6\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 49.575px;\" class=\"xl76\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=3\u0026amp;_sid=0f716b0f9\u0026amp;_ss=r\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(90, 83, 87);\"\u003eAll sensors: Response time T90: \u0026lt; 15 s (CatEx SR: specification for gas methane\/propane)\u003c\/span\u003e\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":43735981752567,"sku":"3703919","price":1230.61,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-x-am-2800-multi-gas-detector-measures-ex-combustible-gases-vapours-o2-oxygen-co-carbon-monoxide-and-h2s-hydrogen-sulphide-p-n-3703919-3703919-1216164091.jpg?v=1768098074"},{"product_id":"3703920-draeger-x-am-2800-basic","title":"Drager X am 2800 Basic P\/N: 3703920","description":"\u003cp class=\"MsoNormal\"\u003e\u003cb\u003e\u003cspan lang=\"EN-US\" style=\"mso-ansi-language: EN-US;\"\u003eThe Drager X am 2800 Multi Gas Detectors are:\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-top: 0cm;\" type=\"disc\"\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eRobust in Design\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eDust \u0026amp; Waterproof (IP 68)\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFall-resistant up to 2 meters\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFast \u0026amp; Durable Sensors\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eFor Oxygen, Flammable and Toxic Gases\u003c\/li\u003e\n\u003cli class=\"MsoNormal\" style=\"mso-list: l0 level1 lfo1; tab-stops: list 36.0pt;\"\u003eWireless Live Monitoring and Fleet Management with Dräger Gas Connect\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"MsoNormal\"\u003e \u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eDraeger X-am 2800, designed for personal protection, is a multi-gas detector that can detect 4 gases. This X am 2800 portable gas detector measures combustible gases\/vapours, O2 (Oxygen), CO (Carbon Monoxide) and H2S (Hydrogen Sulphide).\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X-am 2800 multi-gas detector has a CatEx sensor that is particularly shock-resistant and can monitor up to four gases.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eStrong fleet management and real-time data transfer are provided by the Dräger Gas Detection Connect software.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eThe Drager X-am 2800 is a personal monitoring device that provides the highest level of security at an affordable cost of ownership. It is lightweight and small, making the X-am 2800 easy to use and comfortable.\u003c\/p\u003e\n\u003cp class=\"MsoNormal\"\u003eIncluded in this product detector is Bluetooth function, Power supply (NiMH battery), Charger and plug-in power supply unit (for charging of 1 instrument, P.N. \u003ca rel=\"noopener\" title=\"Drager Charging Set\" href=\"https:\/\/www.isssafety.com\/products\/drager-x-am-charging-set-basic-charging-module-with-single-charger\" target=\"_blank\"\u003e8320333\u003c\/a\u003e). \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSensor information below:  \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eSee the datasheet below for more information.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable height=\"492\" style=\"border-collapse: collapse; width: 632px; height: 484px;\" width=\"585\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 126px;\" span=\"5\" width=\"117\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 34.175px;\" height=\"26\"\u003e\n\u003ctd style=\"height: 34.175px; width: 88pt;\" width=\"117\" class=\"xl67\" height=\"26\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eDrägerSensors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88pt; height: 34.175px;\" width=\"117\" class=\"xl68\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eSample gases\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88pt; height: 34.175px;\" width=\"117\" class=\"xl68\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eMeasuring range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88pt; height: 34.175px;\" width=\"117\" class=\"xl68\"\u003e\u003cstrong\u003e\u003cspan class=\"font5\"\u003eResolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88pt; height: 34.175px;\" width=\"117\" class=\"xl69\"\u003e\u003cstrong\u003ePart No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 148.163px;\" height=\"86\"\u003e\n\u003ctd style=\"height: 148.163px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"86\"\u003e\n\u003cspan class=\"font6\"\u003eCatEx SR (Shock Resistant)\u003c\/span\u003e\u003cspan class=\"font9\"\u003e\u003csup\u003e \u003c\/sup\u003e\u003c\/span\u003e\u003cspan class=\"font6\"\u003e(factory setting: methane, other measuring gases selectable)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 148.163px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eMethane, Further gases adjustable (propane, pentane, nonane, hydrogen and many more)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 148.163px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 100 % LEL\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 148.163px;\" width=\"117\" class=\"xl66\"\u003e\n\u003cspan class=\"font6\"\u003e1 % LEL,\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"font6\"\u003e0.01 % LEL for\u003cbr\u003e\u003c\/span\u003e\u003cspan class=\"font6\"\u003eMethane with selection ch4L (Methane, leak search)\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 148.163px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/6851900-draeger-draegersensor-catex-sr?_pos=1\u0026amp;_sid=5cec978c6\u0026amp;_ss=r\"\u003e6851900\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 26.125px;\" height=\"20\"\u003e\n\u003ctd style=\"height: 26.125px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl72\" height=\"20\"\u003e \u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 26.125px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eMethane\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 26.125px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 5 vol% CH4\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 26.125px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 26.125px;\" width=\"117\" class=\"xl73\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 49.525px;\" height=\"34\"\u003e\n\u003ctd style=\"height: 49.525px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"34\"\u003e\u003cspan class=\"font6\"\u003eXXS O2 (4 alarm thresholds)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.525px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eOxygen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.525px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 25 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.525px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 49.525px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-oxygen-o2?_pos=2\u0026amp;_sid=ea059916b\u0026amp;_ss=r\"\u003e6810881\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 98.8375px;\" height=\"59\"\u003e\n\u003ctd style=\"height: 98.8375px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"59\"\u003e\u003cspan class=\"font6\"\u003eXXS O2 PR (4 alarm thresholds, increased robustness)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 98.8375px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eOxygen\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 98.8375px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 30 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 98.8375px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 vol%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 98.8375px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/draeger-xxs-o2-pr-poison-resistant-0-30-vol?_pos=1\u0026amp;_sid=dbeeb74a0\u0026amp;_ss=r\"\u003e6800530\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.8625px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 24.8625px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"19\"\u003e\u003cspan class=\"font6\"\u003eXXS CO LC\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eCarbon Monoxide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 2.000 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 24.8625px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-carbon-monoxide-co-low-concentration?_pos=3\u0026amp;_sid=e38a42a4b\u0026amp;_ss=r\"\u003e6813210\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 27.875px;\" height=\"22\"\u003e\n\u003ctd style=\"height: 27.875px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"22\"\u003eXXS H2S LC\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 27.875px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eHydrogen Sulphide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 27.875px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 200 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 27.875px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 27.875px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-hydrogen-sulphide-h2s-low-concentration?_pos=4\u0026amp;_sid=45b77f5e3\u0026amp;_ss=r\"\u003e6811525\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 24.8625px;\" height=\"19\"\u003e\n\u003ctd style=\"height: 24.8625px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl70\" height=\"19\"\u003eXXS NO2\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003eNitrogen Dioxide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0 – 50 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 24.8625px;\" width=\"117\" class=\"xl65\"\u003e\u003cspan class=\"font6\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 24.8625px;\" class=\"xl71\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-nitrogen-dioxide-no2?_pos=2\u0026amp;_sid=f7e720bbb\u0026amp;_ss=r\"\u003e6810884\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 49.575px;\" height=\"33\"\u003e\n\u003ctd style=\"height: 49.575px; border-top: none; width: 88pt;\" width=\"117\" class=\"xl74\" height=\"33\"\u003e\u003cspan class=\"font6\"\u003eXXS SO2 (with KX-Filter)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.575px;\" width=\"117\" class=\"xl75\"\u003e\u003cspan class=\"font6\"\u003eSulphur Dioxide\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.575px;\" width=\"117\" class=\"xl75\"\u003e\u003cspan class=\"font6\"\u003e0 – 100 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 88pt; height: 49.575px;\" width=\"117\" class=\"xl75\"\u003e\u003cspan class=\"font6\"\u003e0.1 ppm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"border-top: none; height: 49.575px;\" class=\"xl76\"\u003e\u003ca href=\"https:\/\/www.isssafety.com\/products\/drager-xxs-electrochemical-sensor-sulphur-dioxide-so2?_pos=3\u0026amp;_sid=0f716b0f9\u0026amp;_ss=r\"\u003e6810885\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(90, 83, 87);\"\u003eAll sensors: Response time T90: \u0026lt; 15 s (CatEx SR: specification for gas methane\/propane)\u003c\/span\u003e\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003eAll information is provided by the manufacturer and, while every effort is made to keep it current, we recommend confirming that details suit your needs. \u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(214, 0, 28);\"\u003e\u003cstrong\u003eAs a Drager Sales Channel partner, ISS can offer a range of support services: incl. training, calibrations and services (we are a Dräger Authorised Service Partner (ASP).\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eISS are a leading provider of gas detection and calibration services in Ireland and the UK.\u003c\/span\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":43735981785335,"sku":"3703920","price":897.26,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-3703918-drager-x-am-2800-ex-o2-co-h2s-incl-battery-3703918-1204475201.png?v=1762954793"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/collections\/Drager_x-am_2800.png?v=1771505150","url":"https:\/\/www.isssafety.com\/collections\/drager-x-am-2800.oembed","provider":"Industrial Safety Services","version":"1.0","type":"link"}