{"title":"Dräger Short Term","description":"","products":[{"product_id":"drager-short-term-detection-tubes-acetaldehyde-100-a-pack-of-10","title":"Dräger Tube -Acetaldehyde 100\/a","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Acetaldehyde 100\/A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Acetaldehyde (100\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6726665\u003c\/td\u003e\n\u003ctd\u003eAcetaldehyde 100\/a\u003c\/td\u003e\n\u003ctd\u003eAcetaldehyde\u003c\/td\u003e\n\u003ctd\u003e100 to 1000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIsobutyl Acetate\u003c\/td\u003e\n\u003ctd\u003e100 to 1000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Methylpropan-2-ol\u003c\/td\u003e\n\u003ctd\u003e50 to 500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMethyl-tert-butylether\u003c\/td\u003e\n\u003ctd\u003e100 to 1000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e100 to 1,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eorange to brownish-green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCH3CHO + CrVI ~\u0026gt; CrIII + various products\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe tube does not differentiate between different aldehydes. Ethers, ketones, esters, aromatics and petroleum hydrocarbons are indicated, but with different sensitivities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340085514,"sku":"6726665","price":88.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-acetaldehyde-100-a-6726665-1204476021.png?v=1762928991"},{"product_id":"drager-short-term-detection-tubes-acetic-acid-5-a-pack-of-10","title":"Dräger Tube -Acetic Acid 5\/a tube","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Acetic Acid (5\/a)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Acetic Acid (5\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6722101\u003c\/td\u003e\n\u003ctd\u003eAcetic Acid 5\/a tube\u003c\/td\u003e\n\u003ctd\u003eAcetic Acid\u003c\/td\u003e\n\u003ctd\u003e2 to 9 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAcetic Anhydride\u003c\/td\u003e\n\u003ctd\u003e2-9 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eFormic Acid\u003c\/td\u003e\n\u003ctd\u003e5 to 80 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e5 to 80 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 30 s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eblue violet to yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\u0026lt; 30 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCH3COOH + pH Indicator ~\u0026gt; yellow reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is impossible to measure acetic acid in the presence of other acids. Organic acids are indicated by the same color change, but with different sensitivities. Mineral acids (e.g. hydrochloric acid) are indicated by red discolorations and different sensitivities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg height=\"90\" width=\"76\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340085770,"sku":"6722101","price":89.19,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-acetic-acid-5-a-tube-6722101-1204476046.png?v=1762929000"},{"product_id":"drager-short-term-detection-tubes-acetone-40-a-pack-of-10","title":"Dräger Tube -Acetone 40\/a","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Acetone (40\/a)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Acetone (40\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e40 to 80 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 1 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003epale yellow to yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e5 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e5 to 40 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAcetone + 2.4-Dinitrophenylhydrazine ~\u0026gt; yellow hydrazone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther ketones are indicated but with different sensitivities. Aldehydes are indicated. 500 ppm ethylacetate does not affect the indication. Ammonia causes the indicating layer to turn yellowish brown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340087946,"sku":"8103381","price":74.31,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-acetone-40-a-8103381-1204476019.png?v=1762929110"},{"product_id":"drager-short-term-detection-tubes-acetone-100-b-pack-of-10","title":"Dräger Tube -Acetone 100\/b","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Acetone (100\/b)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Acetone (100\/b).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH22901\u003c\/td\u003e\n\u003ctd\u003eAcetone 100\/b\u003c\/td\u003e\n\u003ctd\u003eAcetone\u003c\/td\u003e\n\u003ctd\u003e100 to 12000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Butanone\u003c\/td\u003e\n\u003ctd\u003e100 to 12000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Heptanone\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eHexone (MIBK)\u003c\/td\u003e\n\u003ctd\u003e130 to 15600 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMethyl-n-Amyl Ketone (2-Heptanone)\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMethyl Ethyl Ketone\u003c\/td\u003e\n\u003ctd\u003e100 to 12000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMethyl Isobutylketone (4-Methyl-2-pentanone)\u003c\/td\u003e\n\u003ctd\u003e130 to 15600 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMethylpropyl Ketone\u003c\/td\u003e\n\u003ctd\u003e130 to 15600 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Pentanone\u003c\/td\u003e\n\u003ctd\u003e130 to 15600 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e100 to 12,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 4 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003epale yellow to yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e5 to 20 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAcetone + 2.4-Dinitrophenylhydrazine ~\u0026gt; yellow hydrazone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther ketones are indicated but with different sensitivities. Aldehydes are indicated, but not esters. Ammonia causes the indicating layer to turn yellowish brown.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340091594,"sku":"CH22901","price":74.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-acetone-100-b-ch22901-1204475973.png?v=1762927664"},{"product_id":"drager-short-term-detection-tubes-acid-test-pack-of-10","title":"Dräger Tube -Acid Test","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Acid Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Acid tests.\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eQualitative identification of acid gases.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 3 s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eblue violet to yellow or pink yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHCl + pH Indicator ~\u0026gt; pink yellow reaction product.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis tube indicates various acid gases with differing sensitivities and colors ranging from yellow to pink. It is impossible to differentiate them.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340092618,"sku":"8101121","price":97.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-acid-test-8101121-1204476042.png?v=1762927674"},{"product_id":"drager-short-term-detection-tubes-amine-test-pack-of-10","title":"Dräger Tube -Amine Test","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Amine Test\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Amine Tests.\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003equalitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 5 s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eyellow to blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAmine + pH indicator ~\u0026gt; blue reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe tube indicates unspecifically basic reacting gases with different sen sitivities. It is impossible to differentiate between the basic reacting gases.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340097034,"sku":"8101061","price":85.16,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-amine-test-8101061-1204476040.png?v=1762927670"},{"product_id":"drager-short-term-detection-tubes-ammonia-0-25-a-pack-of-10","title":"Dräger Tube -Ammonia 0.25.\/a","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Ammonia (0.25\/a)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Ammonia (0.25\/a)\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"25\"\u003e8101711\u003c\/td\u003e\n\u003ctd rowspan=\"25\"\u003eAmmonia 0.25.\/a\u003c\/td\u003e\n\u003ctd\u003eAmmonia\u003c\/td\u003e\n\u003ctd\u003e0.05 to 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAzirdine\u003c\/td\u003e\n\u003ctd\u003e0.25 to 3 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyclohexylamine\u003c\/td\u003e\n\u003ctd\u003e0.45 to 5ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1,2-Diaminoethane\u003c\/td\u003e\n\u003ctd\u003e0.5 to 12 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Diethylaminoethanol\u003c\/td\u003e\n\u003ctd\u003e0.5 to 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiethylenetriamine\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiisopropylamine\u003c\/td\u003e\n\u003ctd\u003e0.5 to 6 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimethylamine\u003c\/td\u003e\n\u003ctd\u003e0.25 to 6 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN,n-Dimethylaminopropylamine\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimethylethanolamine\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimethylethylamine\u003c\/td\u003e\n\u003ctd\u003e0.2 to 2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1,1-Dimethylhydrazine\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimethylisopropylamine\u003c\/td\u003e\n\u003ctd\u003e1 to 12 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDipropylamine\u003c\/td\u003e\n\u003ctd\u003e0.5 to 5.5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthanolamine\u003c\/td\u003e\n\u003ctd\u003e0.5 to 6 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthylenediamine\u003c\/td\u003e\n\u003ctd\u003e0.5 to12 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthyleneimine\u003c\/td\u003e\n\u003ctd\u003e0.25 to 3 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFufurylamine\u003c\/td\u003e\n\u003ctd\u003e0.25 to 3 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHexamethylene Diamine\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2-Methylaminoethanol\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eN-Methyldiethanolamine\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMorpholine\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTriethylamine\u003c\/td\u003e\n\u003ctd\u003e0.25 to 3 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTriethylenetetramine\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrimethylamine\u003c\/td\u003e\n\u003ctd\u003e0.25 to 3 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0.25 to 3 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 1 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eyellow to blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\u0026lt; 20 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNH3 + pH indicator ~\u0026gt; blue reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther basic substances such as e.g. organic amines are indicated as well, but with different sensitivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg height=\"90\" width=\"76\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340097290,"sku":"8101711","price":91.51,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-ammonia-0-25-a-8101711-1204476013.png?v=1762928628"},{"product_id":"drager-short-term-detection-tubes-ammonia-5-a-pack-of-10","title":"Dräger Tube -Ammonia 5\/a","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Ammonia (5\/a)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Ammonia (5\/a)\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH20501\u003c\/td\u003e\n\u003ctd\u003eAmmonia 5\/a\u003c\/td\u003e\n\u003ctd\u003eAmmonia\u003c\/td\u003e\n\u003ctd\u003e1 to 600 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1,1-Dimethylhydrazine\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e5 to 70 ppm \/ 50 to 600 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 \/ 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 60 s. \/ 10s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eyellow to blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\u0026lt; 20 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNH3 + pH indicator ~\u0026gt; blue reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther basic substances such as e.g. organic amines are indicated as well.\u003c\/p\u003e\n\u003cp\u003eThe indication is not affected by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e300 ppm nitrous fumes\u003c\/li\u003e\n\u003cli\u003e2,000 ppm sulfur dioxide\u003c\/li\u003e\n\u003cli\u003e2,000 ppm hydrogen sulfide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340099274,"sku":"CH20501","price":76.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-ammonia-5-a-ch20501-1204476028.png?v=1762928643"},{"product_id":"drager-short-term-detection-tubes-ammonia-5-b-pack-of-10","title":"Dräger Tube -Ammonia 5\/b","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Ammonia (5\/b)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Ammonia (5\/b)\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e5 to 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 10s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eyellow to blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 to 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\u0026lt; 20 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNH3 + pH indicator ~\u0026gt; blue reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther basic substances such as e.g. organic amines are indicated as well.\u003c\/p\u003e\n\u003cp\u003eThe indication is not affected by:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e300 ppm nitrous fumes\u003c\/li\u003e\n\u003cli\u003e2,000 ppm sulfur dioxide\u003c\/li\u003e\n\u003cli\u003e2,000 ppm hydrogen sulfide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eExtension of the Measuring Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsing n = 2 strokes, divide the reading by 2; the measuring range will be 2.5 to 50 ppm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340100170,"sku":"8101941","price":78.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-ammonia-5-b-8101941-1204475878.png?v=1762928754"},{"product_id":"drager-short-term-detection-tubes-ammonia-0-5-a-pack-of-10","title":"Dräger Tube -Ammonia 0.5%\/a","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Ammonia (0.5%\/a)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Ammonia (0.5%\/a)\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0.5 to 10 vol. %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e1 + 1 desorption stroke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e20s. per sroke\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eyellow to violet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 to 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 12 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNH3 + pH indicator ~\u0026gt; purple reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther basic substances such as e.g. organic amines are indicated as well.\u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eExtension of the Measuring Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsing n = 10 + 1 desorptionstroke in clean air divide the reading by 10; the measuring range will be 0.05 to 1 % by vol.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340101002,"sku":"CH31901","price":78.88,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-ammonia-0-5-a-ch31901-1204476003.png?v=1762928760"},{"product_id":"drager-short-term-detection-tubes-aniline-0-5-a-pack-of-10","title":"Dräger Tube -Aniline 0.5\/a","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Aniline (0.5\/a)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Aniline (0.5\/a)\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6733171\u003c\/td\u003e\n\u003ctd\u003eAniline 0.5\/a\u003c\/td\u003e\n\u003ctd\u003eAniline\u003c\/td\u003e\n\u003ctd\u003e0.5 to 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eN,N-Dimethylaniline\u003c\/td\u003e\n\u003ctd\u003e0.5 to 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0.5 to 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 4 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003epale yellow to pale green.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e15 to 30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e7 to 12 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eC6H5NH2 + CrVI ~\u0026gt; CrIII + various oxidation products\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen methyl aniline and aniline are present at the same time, it is impossible to measure only the aniline concentration. Ethers, ketones, esters, aromatics and benzines are indicated as well but with different sensitivities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340102410,"sku":"6733171","price":119.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-aniline-0-5-a-6733171-1204476048.png?v=1762928751"},{"product_id":"drager-short-term-detection-tubes-arsine-0-05-a-pack-of-10","title":"Dräger Tube -Arsine 0.05\/a","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Arsine (0.05\/a)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for Arsine (0.05\/a)\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH25001\u003c\/td\u003e\n\u003ctd\u003eArsine 0.05\/a\u003c\/td\u003e\n\u003ctd\u003eAntimony Hydride\u003c\/td\u003e\n\u003ctd\u003e0.05 to 3ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eArsine\u003c\/td\u003e\n\u003ctd\u003e0.05 to 60 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0.05 to 3 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003eapprox. 6 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003ewhite to greenish-violet.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003emax. 40 mg H2O\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAsH3 + Au3+ ~\u0026gt; Au (colloidal)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhosphine and antimony hydride are indicated as well, but with different sensitivities. Hydrogen sulfide, mercaptans, ammonia and hydrogen chloride in the TLV range do not affect the indication. Carbon monoxide and sulfur dioxides in the TLV range also do not affect the indication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg height=\"90\" width=\"76\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44340107658,"sku":"CH25001","price":102.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-arsine-0-05-a-ch25001-1204475850.png?v=1762928757"},{"product_id":"drager-short-term-detection-tubes-benzene-0-25-a-pack-of-10","title":"Dräger Tube -Benzene 0.25\/a","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Benzene 0.25\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Benzene 0.25\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e0.25 to 2 ppm \/2 to 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003elight grey to dark grey to black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\u0026lt; 40 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBenzene + Alu+ ~\u0026gt; dark grey to black reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUp to a concentration of approx. 40 ppm (n=5) and 200 ppm (n=1), toluene, xylene and ethyl benzole are kept in the pre-layer where they cause a brown discolouration. 800 ppm n-Oktane (n=5) and 4000 ppm n-Octane (n=1) do not cause any discoluration in the indicating layer..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577468746,"sku":"8103691","price":94.12,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-benzene-0-25-a-8103691-1204476044.png?v=1762928877"},{"product_id":"drager-short-term-detection-tubes-benzene-2-a-pack-of-5","title":"Dräger Tube -Benzene 2\/a (5)","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Benzene 2\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Benzene 2\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e2 to 60 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003ewhite to brown grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e1 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eC6H6 + I2O5 + H2SO4 ~\u0026gt; I2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlkyl benzenes such as toluene or xylene up to a concentration of 200 ppm do not affect the indication. It is impossible to measure benzene in the presence of petroleum hydrocarbons and carbon monoxide..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577470666,"sku":"8101231","price":82.07,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-benzene-2-a-5-8101231-1204475954.png?v=1762928864"},{"product_id":"drager-short-term-detection-tubes-benzene-5-a-pack-of-10","title":"Dräger Tube -Benzene 5\/a","description":"\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Benzene 5\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Benzene 5\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e5 to 40 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e15 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003emax. 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003ewhite to red brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003emax. 50 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e2 C6H6 + HCHO ~\u0026gt; C6H5-CH2-C6H5 + H2O C6H5-CH2-C6H5 + H2SO4 ~\u0026gt; p-quinoid compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther aromatics (toluene, xylene) are retained in the pre-layer causing a reddish brown discoloration. If the toluene or xylene concentrations are too high the entire pre-layer up to the indicating layer is discolored making a benzene measurement impossible. Petroleum hydrocarbons, alcohols and esters do not affect the indication..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee datasheet in download below.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577470730,"sku":"6718801","price":82.07,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-benzene-5-a-6718801-1204476017.png?v=1762928880"},{"product_id":"drager-short-term-detection-tubes-benzene-5-b-pack-of-10","title":"Dräger Tube -Benzene 5\/b","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nBenzene 5\/b\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Benzene 5\/b).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n5 to 50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to brown green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n3 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nC6H6 + I205 ~\u0026gt; I2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMany other petroleum hydrocarbons are indicated as well, but with different sensitivities. It is impossible to differentiate them. Other aromatics are indicated as well..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577471050,"sku":"6728071","price":77.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-benzene-5-b-6728071-1204476000.png?v=1762928994"},{"product_id":"drager-short-term-detection-tubes-benzene-15-a-pack-of-10","title":"Dräger Tube -Benzene 15\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nBenzene 15\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Benzene 15\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n15 to 420 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n20 to 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003emax. 4 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to red brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\nmax. 30 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\na) 2 C6H6 + HCHO ~\u0026gt; C6H5-CH2-C6H5 + H2O\nb) C6H5-CH2-C6H5 + H2SO4 ~\u0026gt; p-quinoid compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther aromatics (toluene, xylene) are retained in the pre-layer causing a reddish brown discoloration. If the toluene or xylene concentrations are too high the entire pre-layer up to the indicating layer is discolored making a benzene measurement impossible. Petroleum hydrocarbons, alcohols and esters do not affect the indication..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577471882,"sku":"8101741","price":87.16,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-benzene-15-a-8101741-1204476014.png?v=1762928997"},{"product_id":"drager-short-term-detection-tubes-carbon-dioxide-100-a-pack-of-10","title":"Dräger Tube -Carbon Dioxide 100\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Dioxide 100\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Dioxide 100\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n100 to 3,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 4 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to pale violet\/blue violet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n15 to 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\nmax. 23 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nCO2 + N2H4 ~\u0026gt; NH2-NH-COOH\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo influence on the reading by 10 ppm hydrogen sulfide and 2 ppm sulfur dioxide..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577475658,"sku":"8101811","price":71.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-dioxide-100-a-8101811-1204475962.png?v=1762929003"},{"product_id":"drager-short-term-detection-tubes-carbon-dioxide-0-1-a-pack-of-10","title":"Dräger Tube -Carbon Dioxide 0.1%\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Dioxide 0.1%\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Dioxide 0.1%\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n0.5 to 6 vol. % \/ 0.1 to 1.2 vol. %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 30 s \/ approx. 2.5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 5 to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to violet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\nmax. 30 mg H2O \/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nCO2 + Amine ~\u0026gt; violet reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo influence on the reading by 10 ppm hydrogen sulfide and 2 ppmsulfur dioxide..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577476682,"sku":"CH23501","price":67.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-dioxide-0-1-a-ch23501-1204475953.png?v=1762928988"},{"product_id":"drager-short-term-detection-tubes-carbon-dioxide-0-5-a-pack-of-10","title":"Dräger Tube -Carbon Dioxide 0.5%\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Dioxide 0.5%\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Dioxide 0.5%\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n0.5 to 10 vol. %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 5 to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to violet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\nmax. 50 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nCO2 + amine ~\u0026gt; violet reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHydrogen sulfide in the TLV range does not interfere. In a range comparable to the calibrated range for carbon dioxide, sulfur dioxide is indicated. The sulfur dioxide sensitivity is approximately 1\/3 (e.g. 3 vol. % sulfur dioxide gives an indication of 1 vol. %)..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577477834,"sku":"CH31401","price":65.51,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-dioxide-0-5-a-ch31401-1204475958.png?v=1762929113"},{"product_id":"drager-short-term-detection-tubes-carbon-dioxide-1-a-pack-of-10","title":"Dräger Tube -Carbon Dioxide 1%\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Dioxide 1%\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Dioxide 1%\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n1 to 20 vol. %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 5 to 10 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to violet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\nmax. 40 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nCO2 + N2H4 ~\u0026gt; NH2-NH-COOH\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHydrogen sulfide in the TLV range does not interfere. In a range comparable to the calibrated range for carbon dioxide, sulfur dioxide is indicated. The sulfur dioxide sensitivity is approximately 1\/3 (e.g. 6 vol. % sulfur dioxide gives an indication of 2 vol. %)..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577478730,"sku":"CH25101","price":65.51,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-dioxide-1-a-ch25101-1204475940.png?v=1762929119"},{"product_id":"drager-short-term-detection-tubes-carbon-dioxide-5-a-pack-of-10","title":"Dräger Tube -Carbon Dioxide 5%\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Dioxide 5%\/A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Dioxide 5%\/A).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n5 to 60 vol. %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to violet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\nmax. 50 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nCO2 + N2H4 ~\u0026gt; NH2-NH-COOH\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHydrogen sulphide is not indicated near the limit value. Sulfur dioxide is indicated with comparable concentration range, however, with three times less the sensitivity..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577478986,"sku":"CH20301","price":101.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-dioxide-5-a-ch20301-1204475963.png?v=1762929105"},{"product_id":"drager-short-term-detection-tubes-carbon-disulfide-3-a-pack-of-10","title":"Dräger Tube -Carbon Disulphide 3\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Disulfide 3\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Disulfide 3\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n3 to 95 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n15 to 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003emax. 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\npale blue to yellow green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n\u0026lt; 30 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\n2 CS2 + 4 NHR2 + Cu2+ ~\u0026gt; Cu (SCSNR2)2 + 2 NH2R2+\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHydrogen sulfide in the TLV range is retained in the pre-layer and does not interfere..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577479498,"sku":"8101891","price":102.53,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-disulphide-3-a-8101891-1204475964.png?v=1762927551"},{"product_id":"drager-short-term-detection-tubes-carbon-disulfide-5-a-pack-of-10","title":"Dräger Tube -Carbon Disulphide 5\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Disulfide 5\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Disulfide 5\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n5 to 60 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to brown green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n3 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nCS2 + I2O5 ~\u0026gt; I2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAliphatic and aromatic hydrocarbons, carbon monoxide and hydrogen sulfide are indicated, but with different sensitivities. It is impossible to measure carbon disulfide in the presence of these substances..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577479626,"sku":"6728351","price":88.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-disulphide-5-a-6728351-1204475992.png?v=1762927548"},{"product_id":"drager-short-term-detection-tubes-carbon-disulfide-30-a-pack-of-10","title":"Dräger Tube -Carbon Disulphide 30\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Disulfide 30\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Disulfide 30\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n0.1 to 10 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 1 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\npale blue to brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n\u0026lt; 30 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\n2 CS2 + 4 NHR2 + Cu2+ ~%gt; Cu(SCSNR2)2 + 2 NH2R2+\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHydrogen sulfide is indicated, producing a pale green discoloration. It is impossible to measure carbon disulfide in the presence of hydrogen sulfide..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577480266,"sku":"CH23201","price":88.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-disulphide-30-a-ch23201-1204475959.png?v=1762927559"},{"product_id":"drager-short-term-detection-tubes-carbon-monoxide-2-a-pack-of-10","title":"Dräger Tube -Carbon Monoxide 2\/a","description":"\u003cp\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Carbon Monoxide 2\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Monoxide 2\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6733051\u003c\/td\u003e\n\u003ctd\u003eCarbon Monoxide 2\/a\u003c\/td\u003e\n\u003ctd\u003eCarbon Monoxide\u003c\/td\u003e\n\u003ctd\u003e2 to 300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCarbonyl Sulphide\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"46\" width=\"393\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e2 to 60 ppm \/ 25 to 300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 4 min \/ 50 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003ewhite to brownish pink\/green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e2 to 20 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e5 CO + I2O5 ~\u0026gt; I2 + 5 CO2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following have no influence on the display of 10 ppm CO (respectively): 100 ppm hydrogen sulphide 50 ppm sulphur dioxide 15 ppm nitrogen dioxide 10 ppm CO + 200 ppm octane: display approx. 30 ppm 10 ppm CO + 40 ppm butadiene: display approx. 15 ppm 10 ppm CO +30 (100) ppm benzene: display approx. 15 (20 - 30) ppm 10 ppm CO + 40 ppm chloroform: display approx. 60 ppm 10 (60) ppm acetylene: display approx. 5 (15) ppm With the insertion of a carbon attachment tube (CH 24101), 10ppm CO can still be measured in the presence of 10000 ppm n-octane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg height=\"100\" width=\"76\" alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg height=\"90\" width=\"76\" alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577480842,"sku":"6733051","price":85.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-monoxide-2-a-6733051-1204475968.png?v=1762927554"},{"product_id":"drager-short-term-detection-tubes-carbon-monoxide-5-c-pack-of-10","title":"Dräger Tube -Carbon Monoxide 5\/c","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Monoxide 5\/c\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Monoxide 5\/c).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n100 to 700 \/ 5 to 150 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 50 sec. \/ approx. 150 sec.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to brownish-green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\nmax. 50 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\n5 CO + I2O5 ~ H2S2O7 ~\u0026gt; I2 + 5 CO2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following have no influence on the display of 10 ppm CO (respectively):\n200ppm n-octane, with carbon attachment tube (CH 24101)\n10000 ppm\n30 ppm benzene\n100 ppm hydrogen sulphide\n50 ppm sulphur dioxide\n15 ppm nitrogen dioxide\n40 ppm butadiene\n10 ppm CO + 100 ppm benzene: display approx. 20 ppm\n10 ppm CO + 40 ppm chloroform: display approx. 60 ppm\n10 (60) ppm acetylene: display 8 (20) ppm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577482570,"sku":"CH25601","price":85.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-monoxide-5-c-ch25601-1204475910.png?v=1762927559"},{"product_id":"drager-short-term-detection-tubes-carbon-monoxide-8-a-pack-of-10","title":"Dräger Tube -Carbon Monoxide 8\/a - (for CO in H2 only)","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Monoxide 8\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Monoxide 8\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n8 to 150 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to pale brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n\u0026lt; 50 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\n5 CO + I2O5 ~\u0026gt; I + 5 CO2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAcetylene is also indicated, however, with less sensitivity. Petroleum hydrocarbons, benzene, halogenated hydrocarbons and hydrogen sulfide are retained in the pre-layer. In the case of higher concentrations of interfering hydrocarbons, use should be made of a carbon pre-tube (CH 24 101). Higher concentrations of easily cleavable halogenated hydrocarbons (e.g. trichloroethylene), are liable to form chromyl chloride in the pre-layer which changes the indicating layer to a yellowish-brown. CO determination is impossible in the case of high olefin concentrations..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577482762,"sku":"CH19701","price":93.06,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-monoxide-8-a-for-co-in-h2-only-ch19701-1204475876.png?v=1762927562"},{"product_id":"drager-short-term-detection-tubes-carbon-monoxide-10-b-pack-of-10","title":"Dräger Tube -Carbon Monoxide 10\/b","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Monoxide 10\/b\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Monoxide 10\/b).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n100 to 3,000 \/ 10 to 300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 20 s \/ approx. 4 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to brown green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\nmax. 50 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\n5 CO + I2O5 ~ H2S2O7 ~\u0026gt; I2 + 5 CO2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following have no influence on the display of 10 ppm CO (respectively):\n200ppm n-octane, with carbon attachment tube (CH 24101)\n10000 ppm\n30 ppm benzene\n100 ppm hydrogen sulphide\n50 ppm sulphur dioxide\n15 ppm nitrogen dioxide\n40 ppm butadiene\n10 ppm CO + 100 ppm benzene: display approx. 30 ppm\n10 ppm CO + 40 ppm chloroform: display approx. 35 ppm\n10 (60) ppm acetylene: display 0 (70) ppm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577482890,"sku":"CH20601","price":67.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-monoxide-10-b-ch20601-1204475926.png?v=1762927544"},{"product_id":"drager-short-term-detection-tubes-carbon-monoxide-0-3-b-pack-of-10","title":"Dräger Tube -Carbon Monoxide 0.3%\/b","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Monoxide 0.3%\/b\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Monoxide 0.3%\/b).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n0.3 to 7 vol. % CO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to brown green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\nmax. 50 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\n5 CO + I2O5 ~ H2S2O7 ~\u0026gt; I2 + 5 CO2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following do not influence the display of 0.3 vol. % CO\n10000 ppm n-octane\n300 ppm benzene\n500 ppm hydrogen sulphide\n500 ppm sulphur dioxide\n500 ppm nitrogen dioxide\n300 ppm butadiene\n250 ppm chloroform\n3000 ppm acetylene result in a display of 0.3 vol. %.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577483786,"sku":"CH29901","price":74.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-monoxide-0-3-b-ch29901-1204475919.png?v=1762929108"},{"product_id":"drager-short-term-detection-tubes-carbon-tetrachloride-0-1-a-pack-of-10","title":"Dräger Tube -Carbon tetrachloride 0.1\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCarbon Tetrachloride 0.1\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Tetrachloride 0.1\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n0.1 to 5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 2.5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 20 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nyellow to blue-green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n2 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n1 to 40 mg \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\na) CCI4 + H2S2O7 ~\u0026gt; COCI2\nb) COCI2 + diethylaniline + dimethylaminobenzaldehyde ~\u0026gt; blue-green reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhosgene is displayed with roughtly the same sensivity as carbon tetrachloride.\n50 ppm Tetrachloroethylene will have a display of approx. 1 to 2 ppm, 50 ppm trichloroethylene and 1.1 dichloroethylene will have a weak display of \u0026lt; 0.1 pmm.\nNo indication with:\n- 10 ppm Vinyl Chloride\n- 200 pmm 1.2-Dichloroethylene.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577483914,"sku":"8103501","price":266.95,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-tetrachloride-0-1-a-8103501-1204475969.png?v=1762929116"},{"product_id":"drager-short-term-detection-tubes-carbon-tetrachloride-1-a-pack-of-10","title":"Dräger Tube -Carbon Tetrachloride 1\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Carbon Tetrachloride 1\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Carbon Tetrachloride 1\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8101021\u003c\/td\u003e\n\u003ctd\u003eCarbon Tetrachloride 1\/a\u003c\/td\u003e\n\u003ctd\u003eCarbon Tetrachloride\u003c\/td\u003e\n\u003ctd style=\"font-weight: 400;\"\u003e1 to 15 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eChloropicrine\u003c\/td\u003e\n\u003ctd\u003e1 to 15 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTrichloronitromethane\u003c\/td\u003e\n\u003ctd style=\"font-weight: 400;\"\u003e1 to 15 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e1 to 15 ppm \/ 10 to 50 pmm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 6 min \/ 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003ewhite to yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e15 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ea) CCI4 + H2S2O7 ~\u0026gt; COCI2 b) COCI2 + Aromatic nitrogen compounds ~\u0026gt; yellow reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eChloropicrin and phosgene are indicated with the same sensitivity. It is impossible to measure carbon tetrachloride in the presence of chloropicrin and phosgene. No interference from: 1 ppm chlorine 5 ppm hydrochloric acid 20 ppm methyl bromide 1,000 ppm acetone.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577484490,"sku":"8101021","price":94.68,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-carbon-tetrachloride-1-a-8101021-1204475960.png?v=1762929122"},{"product_id":"drager-short-term-detection-tubes-chlorine-0-2-a-pack-of-10","title":"Dräger Tube -Chlorine 0.2\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Chlorine 0.2\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Chlorine 0.2\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH24301\u003c\/td\u003e\n\u003ctd\u003eChlorine 0.2\/a\u003c\/td\u003e\n\u003ctd\u003eBromine\u003c\/td\u003e\n\u003ctd\u003e0.2 to 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eChlorine\u003c\/td\u003e\n\u003ctd\u003e0.02 to 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eChlorine Dioxide\u003c\/td\u003e\n\u003ctd\u003e0.25 to 2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e0.2 to 3 ppm \/ 3 to 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 3 min \/ 20 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003ewhite to yellow orange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\u0026lt; 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCl2 + o-tolidine ~\u0026gt; yellow orange reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBromine is indicated with the same sensitivity, but with a paler discoloration. Chlorine dioxide is indicated with different sensitivity. Nitrogen dioxide is indicated as well, but with a paler discoloration and lower sensitivity..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577484938,"sku":"CH24301","price":71.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-chlorine-0-2-a-ch24301-1204476038.png?v=1762929235"},{"product_id":"drager-short-term-detection-tubes-chlorine-50-a-pack-of-10","title":"Dräger Tube -Chlorine 50\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Chlorine 50\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Chlorine 50\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePrice\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH20701\u003c\/td\u003e\n\u003ctd\u003eChlorine 50\/a\u003c\/td\u003e\n\u003ctd\u003e69.05\u003c\/td\u003e\n\u003ctd\u003eBromine\u003c\/td\u003e\n\u003ctd\u003e50 to 500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eChlorine\u003c\/td\u003e\n\u003ctd\u003e50 to 500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e50 to 500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 20 s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003egrey green to orange brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\u0026lt; 40 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCl2 + o-tolidine ~\u0026gt; orange brown reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBromine is indicated with the same sensitivity, but with a higher standard deviation ± 25 to 30 %. Chlorine dioxide and nitrogen dioxide are indicated as well, but with different sensitivities..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577486090,"sku":"CH20701","price":86.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-chlorine-50-a-ch20701-1204476020.png?v=1762929241"},{"product_id":"drager-short-term-detection-tubes-chlorine-dioxide-0-025-a-pack-of-10","title":"Dräger Tube -Chlorine Dioxide 0.025\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nChlorine Dioxide 0.025\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Chlorine Dioxide 0.025\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n0.1 to 1 ppm \/ 0.025 to 0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 2.5 min \/ approx. 7.5 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nlight grey to light green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n? 50 mg \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nClO2 + o-Tolidine ~\u0026gt; light green reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following values are not displayed:\n1 ppm Cl2, 10 ppm H2S, 1 ppm SO2,\n10 ppm methyl mercaptane.\n1 ppm bromide is not displayed at a stroke count of n = 10, at n = 30 there is a discoloration of approx. 10 mm..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577486794,"sku":"8103491","price":88.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-chlorine-dioxide-0-025-a-8103491-1204475824.png?v=1762929238"},{"product_id":"drager-short-term-detection-tubes-chlorobenzene-5-a-pack-of-5","title":"Dräger Tube -Chlorobenzene 5\/a (5)","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Chlorobenzene 5\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Chlorobenzene 5\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6728761\u003c\/td\u003e\n\u003ctd\u003eChlorobenzene 5\/a (5)\u003c\/td\u003e\n\u003ctd\u003eBenzyl Chloride\u003c\/td\u003e\n\u003ctd\u003e1 to 15 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eChlorobenzene\u003c\/td\u003e\n\u003ctd\u003e5 to 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1,2-Dichlorobenzene\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1,3-Dichlorobenzene\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1,4-Dichlorobenzene\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e5 to 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 3 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eblue to yellowish-grey\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ea) C6H5Cl + CrVI ~\u0026gt; HCl b) HCl + bromophenol blue ~\u0026gt; yellow reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther chlorinated hydrocarbons are indicated as well, but with different sensitivities. Methylene chloride does not affect the indication. Chlorine and hydrogen chloride in the TLV range are absorbed in the pre-layer, but in such concentrations do not affect the indication..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577486922,"sku":"6728761","price":86.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-chlorobenzene-5-a-5-6728761-1204476002.png?v=1762929225"},{"product_id":"drager-short-term-detection-tubes-chloroform-2-a-pack-of-5","title":"Dräger Tube -Chloroform 2\/a (5)","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nChloroform 2\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Chloroform 2\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n2 to 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 9 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 20 to 30 % at 20 °C and 9 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n10 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n9 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\na) CHCl3 + CrVI ~\u0026gt; Cl2\nb) Cl2 + o-tolidine ~\u0026gt; yellow reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther chlorinated hydrocarbons are indicated, but with different sensitivities..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577487178,"sku":"6728861","price":133.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-chloroform-2-a-5-6728861-1204475966.png?v=1762929230"},{"product_id":"drager-short-term-detection-tubes-chloroformate-0-2-b-pack-of-10","title":"Dräger Tube -Chloroformates 0.2\/b","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nChloroformate 0.2\/b\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Chloroformate 0.2\/b).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n0.2 to 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 3 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 20 to 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n10 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n5 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nCICOOR + 4-(4-nitrobenzyl)-pyridine ~\u0026gt; yellow reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMethyl, ethyl and isopropylchloroformate are indicated with approximately the same sensitivity. It is impossible to differentiate them. Petroleum hydrocarbons, aromatics, alcohols and ketones in the TLV range do not affect the indication. It is impossible to measure chloroformate in the presence of phosgene..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577487306,"sku":"6718601","price":104.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-chloroformates-0-2-b-6718601-1204475974.png?v=1762929242"},{"product_id":"drager-short-term-detection-tubes-chloroprene-5-a-pack-of-10","title":"Dräger Tube -Chloroprene 5\/a","description":"\u003cp\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Chloroprene 5\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Chloroprene 5\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6718901\u003c\/td\u003e\n\u003ctd\u003eChloroprene 5\/a\u003c\/td\u003e\n\u003ctd\u003eButadiene\u003c\/td\u003e\n\u003ctd\u003e0.7 to 8.5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e2-Chloro-1,3-butadiene\u003c\/td\u003e\n\u003ctd\u003e5 to 90 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eChloroprene\u003c\/td\u003e\n\u003ctd\u003e5 to 90 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e1-Hexene\u003c\/td\u003e\n\u003ctd\u003e5 to 60 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIsoprene \u003c\/td\u003e\n\u003ctd\u003e10 to 120 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1-octene\u003c\/td\u003e\n\u003ctd\u003e0.02 to 1 mg\/litre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"46\" width=\"393\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e5 to 60 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e3 + 3 desorption strokes in clean air.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 10 to 15 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eviolet to yellow brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O \/\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCH2=CH-CCI=CH2 + MnO4 – MnIV + various oxidation products\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMany other organic compounds with C=C double bonds are indicated as well, but with different sensitivities. It is impossible to differentiate them. It is impossible to measure chloroprene in the presence of dialkyl sulfides.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg height=\"100\" width=\"76\" alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg height=\"90\" width=\"76\" alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577488778,"sku":"6718901","price":95.41,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-chloroprene-5-a-6718901-1204476006.png?v=1762929229"},{"product_id":"drager-short-term-detection-tubes-chromic-acid-0-1-a-pack-of-9","title":"Dräger Tube -Chromic Acid 0.1\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Chromic Acid 0.1\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Chromic Acid 0.1\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 9 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6728681\u003c\/td\u003e\n\u003ctd\u003eChromic Acid 0.1\/a\u003c\/td\u003e\n\u003ctd\u003eChromic Acid\u003c\/td\u003e\n\u003ctd\u003e0.1 to 0.5 mg\/m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSodium Chromate\u003c\/td\u003e\n\u003ctd\u003e0.1 to 0.5 mg\/m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eSodium Chromate\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1 mg\/m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eZinc Chromate\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1 mg\/m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e0.1 to 0.5 mg\/m3 Discoloration compared to color standard.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 50 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003ewhite to violet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e5 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\u0026lt; 20 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ea) CrO3 + H2SO4 ~\u0026gt; CrVI b) CrVI + diphenylcarbazide ~\u0026gt; CrIII + diphenylcarbazone\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMetal chromates such as zinc or strontium chromate are indicated with about half the sensitivity. CrIII compounds do not affect the indication. Very high chromate concentrations lead to a rapid bleaching of the indication. Measurements should be repeated with less strokes..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577489482,"sku":"6728681","price":153.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-chromic-acid-0-1-a-6728681-1204475944.png?v=1762929345"},{"product_id":"drager-short-term-detection-tubes-cyanide-2-a-pack-of-10","title":"Dräger Tube -Cyanide 2\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCyanide 2\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Cyanide 2\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n2 to 15 mg\/m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n10 (+2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 2.5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 20 to 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nyellow to red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n\u0026lt; 20 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\na) 2 KCN + H2SO4 ~\u0026gt; 2 HCN + K2SO4\nb) 2 HCN + HgCl2 ~\u0026gt; 2 HCI + Hg(CN)2\nc) HCI + methyl red ~\u0026gt; red reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFree hydrogen cyanide is indicated already before breaking the ampoule.\nAcid gases are indicated with different sensitivities.\nA certain portion of the cyanide can have reacted with the CO2 in the air through hydrolysis.\nIt is impossible to measure cyanide in the presence of phosphine..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577489866,"sku":"6728791","price":121.07,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-cyanide-2-a-6728791-1204476016.png?v=1762929355"},{"product_id":"drager-short-term-detection-tubes-cyanogen-chloride-0-25-a-pack-of-10","title":"Dräger Tube -Cyanogen Chloride 0.25\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nCyanogen Chloride 0.25\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Cyanogen Chloride 0.25\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n0.25 to 5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n20 to 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003emax. 5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n± 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to pink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n5 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n\u0026lt; 50 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\na) CICN + pyridine ~\u0026gt; glutaconaldehyde cyanamide\nb) Glutaconaldehyde + barbituric acid ~\u0026gt; pink reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCyanogen bromide is indicated as well, but with a different sensitivity. Calibration data is not available..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577490890,"sku":"CH19801","price":119.32,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-cyanogen-chloride-0-25-a-ch19801-1204475965.png?v=1762931514"},{"product_id":"drager-short-term-detection-tubes-cyclohexylamine-2-a-pack-of-10","title":"Dräger Tube -Cyclohexaylamine 2\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Cyclohexylamine 2\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Cyclohexylamine 2\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years. \u003cbr\u003e\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6728931\u003c\/td\u003e\n\u003ctd\u003eCyclohexaylamine 2\/a\u003c\/td\u003e\n\u003ctd\u003en-Butylamine\u003c\/td\u003e\n\u003ctd\u003e2 to 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCyclohexylamine\u003c\/td\u003e\n\u003ctd\u003e2 to 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIsopropyl Amine \u003c\/td\u003e\n\u003ctd\u003e2 to 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003en-Propylamine \u003c\/td\u003e\n\u003ctd\u003e2 to 30 ppm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eiso-Propylamine\u003c\/td\u003e\n\u003ctd\u003e2 to 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e2 to 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 4 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eyellow to blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e15 to 35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eC6H11NH2 + pH-indicator ~\u0026gt; blue reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther basic substances such as organic amines and ammonia are indicat ed as well..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577492042,"sku":"6728931","price":123.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-cyclohexaylamine-2-a-6728931-1204476051.png?v=1762931504"},{"product_id":"drager-short-term-detection-tubes-diesel-fuel-pack-of-10","title":"Dräger Tube -Diesel Fuel","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: \n\nDiesel Fuel\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Diesel Fuel).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of \n10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n25 to 200 mg\/m3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n: \u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 2.5 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\n-\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e\nwhite to brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\n? 40 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\nUndecane + I2O5 = I2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVarious organic compounds with changing sensitivity are displayed..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577492234,"sku":"8103475","price":64.27,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-diesel-fuel-8103475-1204476043.png?v=1762926231"},{"product_id":"drager-short-term-detection-tubes-diethyl-ether-100-a-pack-of-10","title":"Dräger Tube -Diethyl Ether 100\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Diethyl Ether 100\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Diethyl Ether 100\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6730501\u003c\/td\u003e\n\u003ctd\u003eDiethyl Ether 100\/a\u003c\/td\u003e\n\u003ctd\u003eDibutylether\u003c\/td\u003e\n\u003ctd\u003e200 to 8000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDiethyl Ether\u003c\/td\u003e\n\u003ctd\u003e100 to 4000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eDipropyl ether\u003c\/td\u003e\n\u003ctd\u003e100\/a 100 to 4000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eEther\u003c\/td\u003e\n\u003ctd\u003e100 to 4000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIsopropyl Ether \u003c\/td\u003e\n\u003ctd\u003e100 to 4000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e100 to 4,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eorange to green brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e15 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eC2H5-O-C2H5 + CrVI ~\u0026gt; CrIII + various oxidation products\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMany petroleum hydrocarbons, alcohols, aromatics and esters are indicat ed as well, but with different sensitivities. It is not possible to differentiate between them..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577492618,"sku":"6730501","price":86.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-diethyl-ether-100-a-6730501-1204475948.png?v=1762926228"},{"product_id":"drager-short-term-detection-tubes-dimethyl-formamide-10-b-pack-of-10","title":"Dräger Tube -Dimethyl Formamide 10\/b","description":"\u003cp\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Dimethyl Formamide 10\/b\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Dimethyl Formamide 10\/b).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6718501\u003c\/td\u003e\n\u003ctd\u003eDimethyl Formamide 10\/b\u003c\/td\u003e\n\u003ctd\u003eDimethyl acetamide \u003c\/td\u003e\n\u003ctd\u003e100 to 400 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimethyl Formamide \u003c\/td\u003e\n\u003ctd\u003e2.5 to 80 ppm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"46\" width=\"393\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003e\n\u003cp\u003eStandard Measuring Range:\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e10 to 40 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 20 to 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eyellow to greyblue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e15 to 35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 12 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ea) Dimethylformamide + NaOH ~\u0026gt; NH3 b) NH3 + pH-indicator ~\u0026gt; greyblue reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther basic substances, e.g. ammonia, organicsamines and hydrazine are also indicate, however, with differing sensitivity..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg height=\"100\" width=\"76\" alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg height=\"90\" width=\"76\" alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577492682,"sku":"6718501","price":170.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-dimethyl-formamide-10-b-6718501-1204475915.png?v=1762926240"},{"product_id":"drager-short-term-detection-tubes-dimethyl-sulfate-0-005-c-pack-of-9","title":"Dräger Tube -Dimethyl Sulphate 0.005\/c (9)","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Dimethyl Sulfate 0.005\/c\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Dimethyl Sulfate 0.005\/c).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 9 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6718701\u003c\/td\u003e\n\u003ctd\u003eDimethyl Sulphate 0.005\/c (9)\u003c\/td\u003e\n\u003ctd\u003eDiethyl Sulphate\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimethyl Sulphate \u003c\/td\u003e\n\u003ctd\u003e0.005 to 0.6 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e0.005 to 0.05 ppm Discoloration compared to color standard.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 50 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003ewhite to blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e15 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDimethyl sulphate + 4-(4-Nitrobenzyl)-pyridine Ã¤ colorless alkylation product colorless alkylation product Ã¤ blue reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ePhosgene and chloroformates cause a yellow discoloration of the indicating layer, and it is impossible to perform a dimethyl sulphate measurement. Alcohols, ketones, aromatics and petroleum hydrocarbons in the TLV range do not affect the indication..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577493258,"sku":"6718701","price":180.15,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-dimethyl-sulphate-0-005-c-9-6718701-1204475902.png?v=1762926356"},{"product_id":"drager-short-term-detection-tubes-dimethyl-sulfide-1-a-pack-of-5","title":"Dräger Tube -Dimethyl Sulphide 1\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Dimethyl Sulfide 1\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Dimethyl Sulfide 1\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 5 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6728451\u003c\/td\u003e\n\u003ctd\u003eDimethyl Sulphide 1\/a\u003c\/td\u003e\n\u003ctd\u003eAcetaldehyde\u003c\/td\u003e\n\u003ctd\u003eQuantitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eAcrolein\u003c\/td\u003e\n\u003ctd\u003e0.1 to 10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eDimethyl Sulphide \u003c\/td\u003e\n\u003ctd\u003e1 to 60 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e1 to 15 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 15 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 15 to 30 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eviolet to yellow brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e15 to 30 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e\u0026lt; 20 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e(CH3) 2S + KMnO4 ~\u0026gt; MnIV + various oxidation products\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMany organic compounds with C=C double bonds are indicated as well, but with different sensitivities. It is impossible to differentiate between them. H2S (hydrogen sulfide) is indicated with approximately twice the sensitivity. The tube H2S 5\/b can be used as a filtering tube. Then, with n = 20 pump strokes approx. 30 ppm H2S is retained. Methyl mercaptan is indicated with approximately twice the sensitivity..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577493898,"sku":"6728451","price":88.37,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-dimethyl-sulphide-1-a-6728451-1204475840.png?v=1762926351"},{"product_id":"drager-short-term-detection-tubes-epichlorhydrine-5-c-pack-of-10","title":"Dräger Tube -Epichlorohydrin 5\/b","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Epichlorhydrine 5\/c\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Epichlorhydrine 5\/c).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6728111\u003c\/td\u003e\n\u003ctd\u003eEpichlorohydrin 5\/b\u003c\/td\u003e\n\u003ctd\u003e1-Chloro-2,3-epoxypropane\u003cbr\u003e - see Epichloorhydrin\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eEpichchlorohydrin\u003c\/td\u003e\n\u003ctd\u003e5 to 80 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e5 to 80 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 8 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003epale grey to yellow orange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e10 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e5 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEpichlorohydrin + Cr VI ~\u0026gt; Cl2 Cl2+ o-tolidine ~\u0026gt; yellow orange reaction product\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOther chlorinated hydrocarbons are indicated as well but with different sensitivities. It is not possible to measure epichlorohydrine in the presence of free halogens and hydrogen halides in the TLV range because they are indicated as well. Petroleum hydrocarbons cause low readings..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577495818,"sku":"6728111","price":100.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-epichlorohydrin-5-b-6728111-1204475999.png?v=1762927430"},{"product_id":"drager-short-term-detection-tubes-ethyl-acetate-200-a-pack-of-10","title":"Dräger Tube -Ethyl Acetate 200\/a","description":"\u003cp\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-logo-200-Cropped_large.png?v=1469702669\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDräger Tubes For Short Term Measurements: Ethyl Acetate 200\/a\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDräger Safety offer a massive range of short-term gas detection tubes for the measurement of various gases. This particular set of tubes is for (Ethyl Acetate 200\/a).\u003c\/p\u003e\n\u003cp\u003eThe tubes come in a pack of 10 tubes and have a shelf life of 2 years.\u003c\/p\u003e\n\u003ctable width=\"547\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"64\"\u003e\u003cstrong\u003ePart no\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"118\"\u003e\u003cstrong\u003eDräger Tube\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"164\"\u003e\u003cstrong\u003eSubstance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"137\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCH20201\u003c\/td\u003e\n\u003ctd\u003eEthyl Acetate 200\/a\u003c\/td\u003e\n\u003ctd\u003eAcrylonitrile\u003c\/td\u003e\n\u003ctd\u003e25 to 250 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003ei-Amyl Acetate\u003c\/td\u003e\n\u003ctd\u003e200 to 1000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003en-Amyl Acetate\u003c\/td\u003e\n\u003ctd\u003e200 to 1000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003en-Butyl Acetate\u003c\/td\u003e\n\u003ctd\u003e200 to 3000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eEthyl Acetate\u003c\/td\u003e\n\u003ctd\u003e200 to 9000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIsoamyl Alcohol \u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eIso-Propyl Acetate\u003c\/td\u003e\n\u003ctd\u003e200 to 3000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMethyl Acetate\u003c\/td\u003e\n\u003ctd\u003e200 to 3000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e2,4-Pentanedione\u003c\/td\u003e\n\u003ctd\u003eQualitative\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"393\" height=\"46\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Measuring Range:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e200 to 3,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eNumber of Strokes n:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eTime for Measurement:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eapprox. 5 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eStandard Deviation:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003e± 15 to 20 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 288px;\"\u003eColour Change:\u003c\/td\u003e\n\u003ctd style=\"width: 301px;\"\u003eorange to green brown\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAmbient Operating Conditions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eTemperature:\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e17 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.9032%;\"\u003eAbsolute Humidity\u003c\/td\u003e\n\u003ctd style=\"width: 49.8387%;\"\u003e3 to 15 mg H2O \/ L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction Principle:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCH3COOC2H5 + CrVI ~\u0026gt; CrIII + various oxidation products\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCross Sensitivity:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMany petroleum hydrocarbons, alcohols, aromatics and esters are indicated, but with different sensitivities. It is impossible to differentiate between them..\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor more information on Dräger-Tubes click the image below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube_Handbook_17th_Edition.pdf?11009586301274378927\" target=\"_blank\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/Tube-Handbook-17th-Edition-1_small.png?v=1499255746\" alt=\"\" width=\"76\" height=\"100\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo view our range of Dräger pumps please click below.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.isssafety.com\/collections\/drager-pumps\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/products\/X-act-5000_large.png?v=1499262797\" alt=\"\" width=\"76\" height=\"90\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Dräger","offers":[{"title":"Default Title","offer_id":44577496202,"sku":"CH20201","price":89.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/files\/drager-drager-tube-ethyl-acetate-200-a-ch20201-1204475939.png?v=1762927442"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1096\/4560\/collections\/Drager_Tube_-Acetic_Acid_5a_tube.png?v=1759923684","url":"https:\/\/www.isssafety.com\/collections\/drager-short-term.oembed?page=7","provider":"Industrial Safety Services","version":"1.0","type":"link"}